摘要:
基于图像的腹腔镜器械跟踪通过帮助外科医生和提高患者安全性在计算机和机器人辅助手术中发挥着重要作用。计算机视觉竞赛,如稳健医疗器械分割(ROBUST-MIS)挑战赛,旨在鼓励开发用于此类目的的稳健模型,提供大型,多样化和注释的数据集。迄今为止,大多数现有的医疗器械实例分割模型都是基于两级检测器,这提供了鲁棒的结果,但远不能接近实时(最多每秒5帧(fps))。然而,为了使该方法在临床上适用,实时能力与高精度一起是最大的要求。在本文中,我们提出了注意力机制的YOLACT架构,允许实时实例分割的仪器,提高了准确性的ROBUST-MIS数据集。与2019年ROBUST-MIS挑战赛的获胜者相比,我们提出的方法在鲁棒性得分方面具有竞争力的性能,获得0.313 MI_DSC和0.338 MI_NSD,同时实现实时性能(37 fps)
英文摘要:
Image-based tracking of laparoscopic instruments plays a fundamental role in computer and robotic-assisted surgeries by aiding surgeons and increasing patient safety. Computer vision contests, such as the Robust Medical Instrument Segmentation (ROBUST-MIS) Challenge, seek to encourage the development of robust models for such purposes, providing large, diverse, and annotated datasets. To date, most of the existing models for instance segmentation of medical instruments were based on two-stage detectors, which provide robust results but are nowhere near to the real-time (5 frames-per-second (fps)at most). However, in order for the method to be clinically applicable, real-time capability is utmost required along with high accuracy. In this paper, we propose the addition of attention mechanisms to the YOLACT architecture that allows real-time instance segmentation of instrument with improved accuracy on the ROBUST-MIS dataset. Our proposed approach achieves competitive performance compared to the winner ofthe 2019 ROBUST-MIS challenge in terms of robustness scores,obtaining 0.313 MI_DSC and 0.338 MI_NSD, while achieving real-time performance (37 fps)
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。