电子电离质谱法的自动碎片识别:应用于大气中卤烃的测量
Automated fragment identification for electron ionisation mass spectrometry: application to atmospheric measurements of halocarbons
摘要:
非目标筛选包括在对样品几乎没有先验知识的情况下,在样品中寻找所有存在的可疑或未知物质。这种方法已经在十多年前引入水分析领域,与专用的化合物识别工具一起,但是对于室内和大气痕量气体测量仍然非常稀缺,尽管明确需要更好地了解大气痕量气体组成。一种新的和有效的分析方法是预浓缩样品的气相色谱法(GC),随后是电子电离、高分辨率质谱法(EI-HRMS)。在这项工作中,我们提出了数据分析工具,使自动化的片段公式注释的未知化合物测量GC-EI-HRMS。基于共洗脱质量/电荷碎片,我们开发了一种创新的数据分析方法,使用有效的组合学和图论来可靠地重建碎片的化学式。该方法不需要分子离子的存在,这是不存在的约40%的EI光谱。我们的方法已经在\textgreater 50种卤代烃和烃上进行了训练和验证,这些卤代烃和烃具有3至20个原子和30至330 g mol-1的摩尔质量,测量的质量分辨率约为3500.对于90%的化合物,超过90%的注释片段公式是正确的。错误识别的情况下,可以归因于每个化合物的检测片段的稀缺性或缺乏同位素约束(没有检测到小isotopocule)。我们的方法能够重建最可能的化学式独立于光谱数据库。因此,它证明了EI-HRMS数据对非目标分析的适用性,并为识别数据库中没有EI质谱的物质铺平了道路。我们说明了我们的方法对大气痕量气体的性能,并建议它可能非常适合于许多其他类型的样品。L-GPL许可的Python代码以ALPINAC的名称发布,用于识别非目标大气化合物的ALPINAC过程。
英文摘要:
Non-target screening consists in searching a sample for all present substances, suspected or unknown, with very little prior knowledge about the sample. This approach has been introduced more than a decade ago in the field of water analysis, together with dedicated compound identification tools, but is still very scarce for indoor and atmospheric trace gas measurements, despite the clear need for a better understanding of the atmospheric trace gas composition.For a systematic detection of emerging trace gases in the atmosphere, a new and powerful analytical method is gas chromatography (GC) of preconcentrated samples, followed by electron ionisation, high resolution mass spectrometry (EI-HRMS). In this work, we present data analysis tools to enable automated fragment formula annotation for unknown compounds measured by GC-EI-HRMS. Based on co-eluting mass/charge fragments, we developed an innovative data analysis method to reliably reconstruct the chemical formulae of the fragments, using efficient combinatorics and graph theory. The method does not require the presence of the molecular ion, which is absent in ~40% of EI spectra. Our method has been trained and validated on \textgreater50 halocarbons and hydrocarbons, with 3 to 20 atoms and molar masses of 30 to 330 g mol-1, measured with a mass resolution of approx.~3500. For 90% of the compounds, more than 90% of the annotated fragment formulae are correct. Cases of wrong identification can be attributed to the scarcity of detected fragments per compound or the lack of isotopic constraint (no minor isotopocule detected).Our method enables to reconstruct most probable chemical formulae independently from spectral databases. Therefore, it demonstrates the suitability of EI-HRMS data for non-target analysis and paves the way for the identification of substances for which no EI mass spectrum is registered in databases. We illustrate the performances of our method for atmospheric trace gases and suggest that it may be well suited for many other types of samples. The L-GPL licenced Python code is released under the name ALPINAC for ALgorithmic Process for Identification of Non-targeted Atmospheric Compounds.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。