arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2103.10457physics.ins-det
收藏

自然伽马background radiation对门静脉监测放射性同位素不混合的影响

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

Matthew Weiss, Ming Fang, Yoann Altmann, Marc G. Paff, Angela Di Fulvio

摘要:

国家安全依赖于几层保护。其中最重要的是在边境和港口的交通管制,利用辐射门户监测系统来发现和阻止潜在的走私企图。大多数门户监视器依赖于塑料散热器来检测伽马射线。尽管它们的能量分辨率很差,但它们的成本效益和大尺寸生长的可能性使它们成为RPM中首选的伽马射线探测器。应用于有机闪烁体光谱的解混算法可用于可靠地识别触发警报的裸露和未屏蔽的放射性核素,即使检测到的计数少于1,000个并且同时存在两种或三种核素。在这项工作中,我们实验研究了一个国家的最先进的解混算法的鲁棒性不同的辐射背景光谱,由于不同的大气条件下,在16 $^\circ$ C至28 $^\circ$ C的温度范围。在存在背景的情况下,当检测到来自源的至少1,000个计数时,该算法能够识别三种核素的未知放射性核素混合物中存在的核素。由于可用的计数较少,我们发现估计的核素分数与实际分数之间的差异较大,约为35.9 $\%$。在这些低计数率状态下,由我们的算法与所识别的分数相关联的不确定性可以是确定识别是否可靠或需要更长的测量以增加信噪比的附加有价值的工具。此外,算法识别性能在不同的数据集是一致的,在不同强度和光谱形状的背景类型的存在下的差异可以忽略不计。

英文摘要:

National security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes makes them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1,000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 $^\circ$C to 28 $^\circ$C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1,000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9$\%$ between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑