arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2103.08660eess.SPcs.ITmath.FAmath.IT
收藏

基于FROG测量的分析信号相位恢复

FROG-measurement based phase retrieval for analytic signals

Youfa Li, Yaoshuai Ma, Deguang Han

摘要:

频率分辨光选通(FROG)在光学中被广泛应用于超快脉冲的表征,但在时频分析和信号处理中,特别是在提取事件的瞬时特征时,常常需要考虑解析信号。本文研究了$\Bbb{C}^N$中解析信号的相位恢复问题。在建立了解析信号的FROG-PR的模糊性之后,我们发现偶数长度的解析信号的FROG-PR不同于奇数长度的解析信号的FROG-PR,也不同于具有$B \leq N/2$的$B$ -带限信号的情况。现有的带限信号的方法可以应用于奇数长度的解析信号,但它不适用于偶数长度的情况。借助两个宽松的FROG-PR问题和一种翻译技术,我们开发了一种针对偶数长度解析信号的FROG-PR方法,并证明在这种情况下,通用解析信号可以由它们的$(3N/2+1)$ FROG测量唯一地(直到模糊性)确定。

英文摘要:

While frequency-resolved optical gating (FROG) is widely used in characterizing the ultrafast pulse in optics, analytic signals are often considered in time-frequency analysis and signal processing, especially when extracting instantaneous features of events. In this paper we examine the phase retrieval (PR) problem of analytic signals in $\Bbb{C}^N$ by their FROG measurements. After establishing the ambiguity of the FROG-PR of analytic signals, we found that the FROG-PR of analytic signals of even lengths is different from that of analytic signals of odd lengths, and it is also different from the case of $B$-bandlimited signals with $B \leq N/2$. The existing approach to bandlimited signals can be applied to analytic signals of odd lengths, but it does not apply to the even length case. With the help of two relaxed FROG-PR problems and a translation technique, we develop an approach to FROG-PR for the analytic signals of even lengths, and prove that in this case the generic analytic signals can be uniquely (up to the ambiguity) determined by their $(3N/2+1)$ FROG measurements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑