Demonstration of a uniform, high-pressure, high-temperature gas cell with a dual frequency comb absorption spectrometer
Ryan K. Cole, Anthony D. Draper, Paul J. Schroeder, Cameron M. Casby, Amanda S. Makowiecki, Sean C. Coburn, Julie E. Steinbrenner, Nazanin Hoghooghi, Gregory B. Rieker
Accurate absorption models for gases at high pressure and temperature support advanced optical combustion diagnostics and aid in the study of harsh planetary atmospheres. Developing and validating absorption models for these applications requires recreating the extreme temperature and pressure conditions of these environments in static, uniform, well-known conditions in the laboratory. Here, we present the design of a new gas cell to enable reference-quality absorption spectroscopy at high pressure and temperature. The design centers on a carefully controlled quartz sample cell housed at the core of a pressurized ceramic furnace. The half-meter sample cell is relatively long compared to past high- pressure and temperature absorption cells, and is surrounded by a molybdenum heat spreader that enables high temperature uniformity over the full length of the absorbing gas. We measure the temperature distribution of the sample gas using in situ thermocouples, and fully characterize the temperature uniformity across a full matrix of conditions up to 1000 K and 50 bar. The results demonstrate that the new design enables highly uniform and precisely known conditions across the full absorbing path length. Uniquely, we test the new gas cell with a broadband, high-resolution dual frequency comb spectrometer that enables highly resolved absorption spectroscopy across a wide range of temperature and pressure conditions. With this system, we measure the spectrum of CO$_2$ between 6800 and 7000 cm$^{-1}$ at pressures between 0.2 and 20 bar, and temperatures up to 1000 K. The measurements reveal discrepancies from spectra predicted by the HITRAN2016 database with a Voigt line shape at both low- and high-pressure conditions. These results motivate future work to expand absorption models and databases to accurately model high-pressure and -temperature spectra in combustion and planetary science research.
Fully stabilized 25 GHz frequency comb for frequency calibration of optical spectrum analyzer
Korea Research Institute of Standards and Science (KRISS)(韩国计量科学研究院);University of Science and Technology (UST)(韩国科学技术院);Chungnam National University(忠南国立大学);Chung-Ang University(中央大学)
高频电子源与现代微波仪器相结合,使得最近能够开发出毫米和太赫兹波段的啁啾脉冲光谱仪。这种类型的仪器可以在高分辨率下操作,这特别适合于气相旋转光谱。本文详细介绍了一台工作在200 GHz的啁啾脉冲谱仪的结构,着重讨论了它的相稳定性和多周期数据积累问题。使用硫化羰的验证允许将仪器的检测限确定为累积的函数。使用10 GHz啁啾脉冲识别了大量OCS跃迁,包括6个最丰富的同位素体,最弱的线对应于16 O 13 C 33 S的基本R(17)跃迁,线强度为4.3 x 10-26 cm-1 /(molec.cm-2)。不同程度的数据积累和过渡线强度的系统响应的线性度被证实超过4个数量级。一个简单的分析的时域数据被证明提供线展宽系数,而不需要通过傅立叶变换的转换。最后,脉冲宽度进行了讨论,并给出了多普勒限制和碰撞制度的最佳值。
具有高光谱分辨率的快(亚秒)光谱技术对于揭示复杂化学和生物反应的量子化学动力学具有重要意义。傅里叶变换(FT)光谱仪可以实现高光谱分辨率,并在快速扫描模式下以数百ms的时间尺度运行。然而,扫描镜的线性平移对这些系统施加了严格的时间分辨率限制,这使得同时高光谱和时间分辨率是不可能的。在这里,我们展示了一个FT光谱仪的工作原理是基于连续旋转,而不是线性,扫描镜的运动,从时间的光谱分辨率去耦。这使得在亚ms时间尺度上的0.5 cm ${}^{-1}$分辨率成为可能。此外,我们表明,这种旋转FT光谱仪可以执行双梳光谱与一个单一的梳源,因为多普勒频移版本的梳作为第二梳。以这种方式,我们结合了双梳和FT光谱的优点,使用一个单一的量子级联激光频率梳作为光源。我们的技术不需要任何衍射或色散光学元件,因此保留了FT光谱仪的Jacquinot,Fellgett和Connes的优点。该系统支持从可见光到THz频率的大光学带宽。旋转延迟线与准直相干或非相干光源的组合为FT光谱仪在需要高速、大光学带宽和高光谱分辨率的应用中铺平了道路。