arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2102.01658nucl-exphysics.atom-ph
收藏

中子电偶极矩实验中的约翰逊-奈奎斯特噪声效应

Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments

N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, P. -J. Chiu, B. Clement, C. B. Crawford, M. Daum, S. Emmenegger, M. Fertl, A. Fratangelo, W. C. Griffith, Z.… 展开作者

N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, P. -J. Chiu, B. Clement, C. B. Crawford, M. Daum, S. Emmenegger, M. Fertl, A. Fratangelo, W. C. Griffith, Z. D. Grujić, P. G. Harris, K. Kirch, P. A. Koss, B. Lauss, T. Lefort, P. Mohanmurthy, O. Naviliat-Cuncic, D. Pais, F. M. Piegsa, G. Pignol, D. Rebreyend, I. Rienäcker, D. Ries, S. Roccia, K. U. Ross, D. Rozpedzik, P. Schmidt-Wellenburg, A. Schnabel, N. Severijns, B. Shen, R. Tavakoli Dinani, J. A. Thorne, R. Virot, N. Yazdandoost, J. Zejma, G. Zsigmond

摘要:

在中子电偶极矩(nEDM)实验中,用于产生静态电场的金属电极产生的磁性约翰逊-奈奎斯特噪声(JNN)会限制测量的灵敏度。在这里,我们提出了第一个专门的研究JNN应用到一个大规模的长测量时间的实验与实施的共同磁力。在这项研究中,我们推导出表面和体积平均均方根正常噪声振幅在一定的频率带宽的圆柱形几何形状。此外,我们模拟的噪声源作为一个有限数量的电流偶极子,并展示了一种方法来模拟时间和三维空间依赖的JNN。计算应用于估计JNN的影响,测量与新的设备,n2 EDM,在保罗谢勒研究所。我们证明了将用于该装置的光泵$^{133}$ Cs磁强计和$^{199}$ Hg共磁强计的性能不受JNN的限制。此外,我们发现,在测量部署一个共同的磁强计系统,JNN的影响是可以忽略不计的nEDM搜索下降到$4\,\times\,10^{-28}\,e\cdot{\rm cm}$的灵敏度在一个单一的测量,因此,使用经济和机械上有利的固体铝电极是可能的。

英文摘要:

Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and volume-averaged root-mean-square normal noise amplitudes at a certain frequency bandwidth for a cylindrical geometry. In addition, we model the source of noise as a finite number of current dipoles and demonstrate a method to simulate temporal and three-dimensional spatial dependencies of JNN. The calculations are applied to estimate the impact of JNN on measurements with the new apparatus, n2EDM, at the Paul Scherrer Institute. We demonstrate that the performances of the optically pumped $^{133}$Cs magnetometers and $^{199}$Hg co-magnetometers, which will be used in the apparatus, are not limited by JNN. Further, we find that in measurements deploying a co-magnetometer system, the impact of JNN is negligible for nEDM searches down to a sensitivity of $4\,\times\,10^{-28}\,e\cdot{\rm cm}$ in a single measurement; therefore, the use of economically and mechanically favored solid aluminum electrodes is possible.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑