时域全波形反演的高分辨率乳腺三维超声成像
High Resolution 3D Ultrasonic Breast Imaging by Time-Domain Full Waveform Inversion
摘要:
超声断层扫描(UST)扫描仪允许定量图像的人类乳房的声学特性,以获得潜在的应用,在筛选,诊断和治疗计划。时域全波形反演(TD-FWI)是一种很有前途的超声波成像技术,它通过基于梯度的优化来拟合波动物理模型的参数场。对于高分辨率3D UST,它面临三个关键挑战:首先,其中心构建块,即单个US测量的梯度计算,具有限制性的大内存占用。其次,需要为每个$10^3-10^4$测量计算该构建块,导致通常在大型计算集群上执行的大规模并行计算持续数天。最后,基础最优化问题的结构可能导致求解器的缓慢进展和收敛到局部极小值。在这项工作中,我们设计和评估了一个全面的计算策略,以克服这些挑战:首先,我们利用梯度计算的基础上的时间反转,大大减少了内存占用的代价是一个额外的波模拟每个源。其次,我们打破了依赖于测量的数量使用源编码(SE)计算随机梯度估计。此外,我们描述了一个更准确的,TD特定的SE技术与更精细的方差控制,并使用一个国家的最先进的随机LBFGS方法。最后,我们设计了一个有效的TD多重网格格式,并结合预处理来加快收敛速度,同时避免局部极小。所有组件都在广泛的数值概念验证研究中进行了评估,模拟了碗状3D UST乳腺扫描仪原型。最后,我们证明了它们的组合使我们能够在24小时内使用Matlab在单个GPU上获得分辨率为0.5mm的精确的442 x442 x222体素图像。
英文摘要:
Ultrasound tomography (UST) scanners allow quantitative images of the human breast's acoustic properties to be derived with potential applications in screening, diagnosis and therapy planning. Time domain full waveform inversion (TD-FWI) is a promising UST image formation technique that fits the parameter fields of a wave physics model by gradient-based optimization. For high resolution 3D UST, it holds three key challenges: Firstly, its central building block, the computation of the gradient for a single US measurement, has a restrictively large memory footprint. Secondly, this building block needs to be computed for each of the $10^3-10^4$ measurements, resulting in a massive parallel computation usually performed on large computational clusters for days. Lastly, the structure of the underlying optimization problem may result in slow progression of the solver and convergence to a local minimum. In this work, we design and evaluate a comprehensive computational strategy to overcome these challenges: Firstly, we exploit a gradient computation based on time reversal that dramatically reduces the memory footprint at the expense of one additional wave simulation per source. Secondly, we break the dependence on the number of measurements by using source encoding (SE) to compute stochastic gradient estimates. Also we describe a more accurate, TD-specific SE technique with a finer variance control and use a state-of-the-art stochastic LBFGS method. Lastly, we design an efficient TD multi-grid scheme together with preconditioning to speed up the convergence while avoiding local minima. All components are evaluated in extensive numerical proof-of-concept studies simulating a bowl-shaped 3D UST breast scanner prototype. Finally, we demonstrate that their combination allows us to obtain an accurate 442x442x222 voxel image with a resolution of 0.5mm using Matlab on a single GPU within 24h.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。