arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2102.00562q-bio.BMphysics.app-ph
收藏

基于银普鲁士蓝修饰TiO $_2$纳米管阵列的新型抗菌电化学葡萄糖生物传感器

A Novel Antimicrobial Electrochemical Glucose Biosensor Based on Silver-Prussian Blue Modified TiO$_2$ Nanotube Arrays

Nasim Farajpour, Ram Deivanayagam, Abhijit Phakatkar, Surya Narayanan, Reza Shahbazian-Yassar, Tolou Shokuhfar

摘要:

葡萄糖生物传感器在糖尿病的诊断和持续监测中发挥着重要作用。本报告提出了一种新的酶电化学葡萄糖生物传感器的基础上,TiO $_2$纳米管改性的氧化银和普鲁士蓝(PB)纳米粒子(NPs),具有额外的优势,具有抗菌性能的植入式生物传感器的应用。在这项研究中,我们开发了两个高性能的葡萄糖生物传感器的基础上固定葡萄糖氧化酶(GOx)普鲁士蓝(PB)修饰的TiO $_2$纳米管阵列功能化的Au和AgO纳米粒子。采用电化学阳极氧化法和电镀银法在相同的电解液中制备了氧化银沉积的TiO $_2$纳米管。从酸性铁氰化物溶液中进行PB颗粒的沉积。通过扫描电子显微镜(SEM)和能量色散X射线光谱(EDS),这表明成功沉积的Au和AgO纳米粒子以及PB纳米晶体的表面形貌和元素组成的两个制造的生物传感器进行了研究。采用循环伏安法和计时电流法研究了修饰后的电化学生物传感器的性能。结果表明,所研制的电化学生物传感器具有良好的电子传输性能,检测限低,以及高稳定性的葡萄糖测定。在优化的条件下,电流响应与葡萄糖浓度呈线性关系,检测限为4.91 $μ$ M,灵敏度为185.1 mA M $^{-1}$ cm $^{-2]$,检测限为58.7 $μ$ M,灵敏度为29.1 mA M $^{-1}$ cm $^{-2]$.

英文摘要:

Glucose biosensors play an important role in the diagnosis and continued monitoring of the disease, diabetes mellitus. This report proposes the development of a novel enzymatic electrochemical glucose biosensor based on TiO$_2$ nanotubes modified by AgO and Prussian blue (PB) nanoparticles (NPs), which has an additional advantage of possessing antimicrobial properties for implantable biosensor applications. In this study, we developed two high performance glucose biosensors based on the immobilization of glucose oxidase (GOx) onto Prussian blue (PB) modified TiO$_2$ nanotube arrays functionalized by Au and AgO NPs. AgO-deposited TiO$_2$ nanotubes were synthesized through an electrochemical anodization process followed by Ag electroplating process in the same electrolyte. Deposition of PB particles was performed from an acidic ferricyanide solution. The surface morphology and elemental composition of the two fabricated biosensors were investigated by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) which indicate the successful deposition of Au and AgO nanoparticles as well as PB nanocrystals. Cyclic voltammetry and chronoamperometry were used to investigate the performance of the modified electrochemical biosensors. The results show that the developed electrochemical biosensors display excellent properties in terms of electron transmission, low detection limit as well as high stability for the determination of glucose. Under the optimized conditions, the amperometric response shows a linear dependence on the glucose concentration to a detection limit down to 4.91 $μ$M with sensitivity of 185.1 mA M$^{-1}$ cm$^{-2]$ in Au modified biosensor and detection limit of 58.7 $μ$M with 29.1 mA M$^{-1}$ cm$^{-2]$ sensitivity in AgO modified biosensor.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑