基于皮肤标记物的受试者特定脊柱对线建模:可行性研究

Skin marker-based subject-specific spinal alignment modeling: A feasibility study

Stefan Schmid, Lukas Connolly, Greta Moschini, Michael L. Meier, Marco Senteler

摘要:

肌肉骨骼模型有可能通过预测个体的准确结果来改善诊断和优化临床治疗。然而,脊柱对准的受试者特定建模通常被强烈简化或基于放射学评估,使受试者暴露于不必要的辐射。因此,我们开发了一种新的基于皮肤标记的方法,用于对受试者特定的脊柱对线进行建模,并通过使用侧位影像学图像将预测与实际椎间关节(IVJ)位置/方向(地面实况)进行比较来评估其可行性。此外,通过将各种功能活动期间预测的L1/L2脊柱载荷与从OrthoLoad数据库获得的体内测量数据进行比较,评价了受试者特定模型的预测性能。与标准模型缩放相比,IVJ位置/方向的预测更接近地面实况,其中在正面上的平均位置预测误差为0.99+/-0.68 cm,在横轴上的平均位置预测误差为1.21+/-0.97 cm,以及平均方向预测误差为4.74°+/-2.80°。模拟脊柱载荷显示出相似的曲线模式,但与体内测量数据相比,数值大得多。通用和受试者特定模型之间的脊柱载荷差异仅在个体受试者水平上变得明显。这些结果强调了所提出的方法和相关的工作流程的可行性,使用肌肉骨骼模拟之间和受试者内的调查。当实施到标准模型缩放工作流程中时,预计将提高肌肉活动和关节负荷模拟的准确性,这对于研究治疗效果或病理依赖性偏差至关重要。

英文摘要:

Musculoskeletal models have the potential to improve diagnosis and optimize clinical treatment by predicting accurate outcomes on an individual basis. However, the subject-specific modeling of spinal alignment is often strongly simplified or is based on radiographic assessments, exposing subjects to unnecessary radiation. We therefore developed a novel skin marker-based approach for modeling subject-specific spinal alignment and evaluated its feasibility by comparing the predicted with the actual intervertebral joint (IVJ) locations/orientations (ground truth) using lateral-view radiographic images. Moreover, the predictive performance of the subject-specific models was evaluated by comparing the predicted L1/L2 spinal loads during various functional activities with in vivo measured data obtained from the OrthoLoad database. IVJ locations/orientations were predicted closer to ground truth as opposed to standard model scaling, with average location prediction errors of 0.99+/-0.68 cm on the frontal and 1.21+/-0.97 cm on the transverse axis as well as an average orientation prediction error of 4.74°+/-2.80°. Simulated spinal loads showed similar curve patterns but considerably larger values as compared to in vivo measured data. Differences in spinal loads between generic and subject-specific models become only apparent on an individual subject level. These results underline the feasibility of the proposed method and associated workflow for inter- and intra-subject investigations using musculoskeletal simulations. When implemented into standard model scaling workflows, it is expected to improve the accuracy of muscle activity and joint loading simulations, which is crucial for investigations of treatment effects or pathology-dependent deviations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑