arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2012.12712eess.IVcs.CV

Chest x-ray automated triage: a semiologic approach designed for clinical implementation, exploiting different types of labels through a combination of four Deep Learning architectures

Hospital Italiano de Buenos Aires(布宜诺斯艾利斯意大利医院);Universidad Tecnológica Nacional(国家技术大学)
Candelaria Mosquera, Facundo Nahuel Diaz, Fernando Binder, Jose Martin Rabellino, Sonia Elizabeth Benitez, Alejandro Daniel Beresñak, Alberto Seehaus, Gabriel D… 展开作者

Candelaria Mosquera, Facundo Nahuel Diaz, Fernando Binder, Jose Martin Rabellino, Sonia Elizabeth Benitez, Alejandro Daniel Beresñak, Alberto Seehaus, Gabriel Ducrey, Jorge Alberto Ocantos, Daniel Roberto Luna

英文摘要:

BACKGROUND AND OBJECTIVES: The multiple chest x-ray datasets released in the last years have ground-truth labels intended for different computer vision tasks, suggesting that performance in automated chest-xray interpretation might improve by using a method that can exploit diverse types of annotations. This work presents a Deep Learning method based on the late fusion of different convolutional architectures, that allows training with heterogeneous data with a simple implementation, and evaluates its performance on independent test data. We focused on obtaining a clinically useful tool that could be successfully integrated into a hospital workflow. MATERIALS AND METHODS: Based on expert opinion, we selected four target chest x-ray findings, namely lung opacities, fractures, pneumothorax and pleural effusion. For each finding we defined the most adequate type of ground-truth label, and built four training datasets combining images from public chest x-ray datasets and our institutional archive. We trained four different Deep Learning architectures and combined their outputs with a late fusion strategy, obtaining a unified tool. Performance was measured on two test datasets: an external openly-available dataset, and a retrospective institutional dataset, to estimate performance on local population. RESULTS: The external and local test sets had 4376 and 1064 images, respectively, for which the model showed an area under the Receiver Operating Characteristics curve of 0.75 (95%CI: 0.74-0.76) and 0.87 (95%CI: 0.86-0.89) in the detection of abnormal chest x-rays. For the local population, a sensitivity of 86% (95%CI: 84-90), and a specificity of 88% (95%CI: 86-90) were obtained, with no significant differences between demographic subgroups. We present examples of heatmaps to show the accomplished level of interpretability, examining true and false positives.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑