We present theoretical description of Voigt and Faraday effect based optically pumped magnetometers using the Floquet expansion. Our analysis describes the spin-operator dynamics of the first, $\hat{F}(t)$, and second, $\hat{F}^2(t)$, order moments and takes into account of different pumping profiles and decoherence effects. We find that the theoretical results are in good agreement with the experimental demonstrations over a wide range of fields and pumping conditions. Finally, the theoretical analysis presented here is generalized and can be extended to different magnetometry schemes with arbitrary pumping profiles and multiple radio-frequency fields.
We described a novel technique that can find the zero-field for unshielded laser-pumped atomic magnetometer using atomic signal itself. By comparing light density of pump beam after atomic vapor cell, it is decided which direction to move the compensation magnetic field and whether to increase or decrease the converging step length. The zero-field is found in less than 18s and the step length after converging is smaller than 10nT, 10nT and 40nT for x, y and z axes, respectively, limited by 50Hz noise in the lab environment.
An atomic magnetometer operated with elliptically polarized light is investigated theoretically and experimentally. To explore the potential of this magnetometric configuration, the analytical form of the outgoing signal is derived. Parameters that significantly influence the performance are optimized, which lead to a sensitivity of 300 $\rm fT/\sqrt{Hz}$ at 45 $^{\circ}$C with a 2$\times$2$\times2$ cm uncoated Rb vapor cell. It is remarkable that a sensitivity of 690 $\rm fT/\sqrt{Hz}$ is achieved at room temperature of 24 $^{\circ}$C, which is improved by an order of magnitude compared with …
We study the effect of optical polarization squeezing on the performance of a sensitive, quantum-noise-limited optically pumped magnetometer. We use Bell-Bloom (BB) optical pumping to excite a $^{87}$Rb vapor containing $8.2 \cdot 10^{12} \mathrm{atoms/cm^3}$ and Faraday rotation to detect spin precession. The sub-$\mathrm{pT}/\sqrt{\mathrm{Hz}}$ sensitivity is limited by spin projection noise (photon shot noise) at low (high) frequencies. Probe polarization squeezing both improves high-frequency sensitivity and increases measurement bandwidth, with no loss of sensitivity at any frequency, a d…
Optically pumped magnetometers are becoming a promising alternative to cryogenically-cooled superconducting magnetometers for detecting and imaging biomagnetic fields. Magnetic field detection is a completely non-invasive method, which allows one to study the function of excitable human organs with a sensor placed outside the human body. For instance, magnetometers can be used to detect brain activity or to study the activity of the heart. We have developed a highly sensitive miniature optically pumped magnetometer based on cesium atomic vapor kept in a paraffin-coated glass container. The mag…
Sensitivity Scaling and Limits of Cavity Enhancement in Miniaturized Optically Pumped Magnetometers
ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology(光子科学研究所,巴塞罗那科技研究院);ICREA - Institució Catalana de Recerca i Estudis Avançats(加泰罗尼亚高级研究学院)
The detection of environmental magnetic fields is well established by optically pumped atomic magnetometers. Another focus of magnetometry can be the research on magnetic or spin-active solid-state samples. Here we introduce a simple and compact design of a rubidium-based M$_{\mathrm{x}}$-magnetometer, which allows for hosting solid-state samples. The optical, mechanical and electrical design is reported, as well as simple measurements which introduce the ground-state spin-relaxation time, the signal-to-noise ratio of a measurement, and subsequently the overall sensitivity of the magnetometer.…
Recording the moving MEGs of a person in which a person's head could move freely as we record the brain's magnetic field is a hot topic in recent years. Traditionally, atomic magnetometers are utilized for moving MEGs recording and a large compensation coil system is utilized for background magnetic field compensation. Here we described a new potential candidate: an optically pumped atomic co-magnetometer(OPACM) for moving MEGs recording. In the OPACM, hyper-polarized nuclear spins could produce a magnetic field which will shield the background fluctuation low frequency magnetic field noise wh…
This article is designed as a step-by-step guide to optically pumped magnetometers based on alkali atomic vapor cells. We begin with a general introduction to atomic magneto-optical response, as well as expected magnetometer performance merits and how they are affected by main sources of noise. This is followed by a brief comparison of different magnetometer realizations and an overview of current research, with the aim of helping readers to identify the most suitable magnetometer type for specific applications. Next, we discuss some practical considerations for experimental implementations, u…
The response of a SERF atomic magnetometer to a repetitive short-pulsed pump was investigated. Quantum sub-resonances at a repetition rate of $1/n$ of the Larmor frequency of the magnetic field inside the shield are experimentally observed and theoretically explained. This is a type of synchronization phenomenon. Investigations in single alkali atoms cells as well as mixed alkali atoms of K and Rb are presented. In the later, one species is pumped while the probe is on the other specie polarized by spin exchange. The effect of spin destruction, spin exchange and collisions are studied in order…
State-of-the-art magnetic field measurements performed in shielded environments with carefully controlled conditions rarely reflect the realities of those applications envisioned in the introductions of peer-reviewed publications. Nevertheless, significant advances in magnetometer sensitivity have been accompanied by serious attempts to bring these magnetometers into the challenging working environments in which they are often required. This review discusses the ways in which various (predominantly optically-pumped) magnetometer technologies have been adapted for use in a wide range of noisy a…
The functioning of the human brain, nervous system and heart is based on the conduction of electrical signals. These electrical signals also create magnetic fields which extend outside the human body. Highly sensitive magnetometers, such as superconducting quantum interference device magnetometers or optically pumped magnetometers, placed outside the human body can detect these biomagnetic fields and provide non-invasive measurements of e.g. brain activity, nerve impulses, and cardiac activity. Animal models are used widely in medical research, including for disease diagnostics and for drugs t…
The heading error has been known to be caused mainly by the nonlinear Zeeman effect and the orientation-dependent light shift. In this work, we find that the nuclear Zeeman effect can also have a significant impact on the heading errors, especially for continuously-driving magnetometers with unresolved magnetic transitions. It not only shifts the precession frequency but deforms the heading errors and causes asymmetry: the heading errors for pump lasers with opposite helicities are different. The heading error also depends on the relative direction (parallel or vertical) of the probe laser to …
We explore adiabatic pumping in the presence of periodic drive, finding a new phase in which the topologically quantized pumped quantity is energy rather than charge. The topological invariant is given by the winding number of the micromotion with respect to time within each cycle, momentum, and adiabatic tuning parameter. We show numerically that this pump is highly robust against both disorder and interactions, breaking down at large values of either in a manner identical to the Thouless charge pump. Finally, we suggest experimental protocols for measuring this phenomenon.
The energy resolution per bandwidth $E_R$ is a figure of merit that combines the field resolution, bandwidth or duration of the measurement, and size of the sensed region. Several different dc magnetometer technologies approach $E_R = \hbar$, while to date none has surpassed this level. This suggests a technology-spanning quantum limit, a suggestion that is strengthened by model-based calculations for nitrogen-vacancy centres in diamond, for superconducting quantum interference device (SQUID) sensors, and for some optically-pumped alkali-vapor magnetometers, all of which predict a quantum limi…
We investigate the effect of dissipation from a thermal environment on topological pumping in the periodically-driven Rice-Mele model. We report that dissipation can improve the robustness of pumping quantisation in a regime of finite driving frequencies. Specifically, in this regime, a low-temperature dissipative dynamics can lead to a pumped charge that is much closer to the Thouless quantised value, compared to a coherent evolution. We understand this effect in the Floquet framework: dissipation increases the population of a Floquet band which shows a topological winding, where pumping is e…
Quadrature-detected zero-to-ultralow-field nuclear magnetic resonance
Physikalisch-Technische Bundesanstalt (PTB)(德国联邦物理技术研究院);New York University(纽约大学);North Carolina State University(北卡罗来纳州立大学);Jagiellonian University in Kraków(克拉科夫雅盖隆大学);Johannes Gutenberg University of Mainz(美因茨约翰内斯·古腾堡大学)