arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2011.02874cs.SDcs.LGeess.AS

Influence of Event Duration on Automatic Wheeze Classification

Univ Coimbra(科英布拉大学);Univ Aveiro(阿威罗大学);CISUC(CISUC机构);Lab3R(Lab3R机构);DEI(DEI机构);ESSUA(ESSUA机构);iBiMED(iBiMED机构)

Bruno M. Rocha, Diogo Pessoa, Alda Marques, Paulo Carvalho, Rui Pedro Paiva

英文摘要:

Patients with respiratory conditions typically exhibit adventitious respiratory sounds, such as wheezes. Wheeze events have variable duration. In this work we studied the influence of event duration on wheeze classification, namely how the creation of the non-wheeze class affected the classifiers' performance. First, we evaluated several classifiers on an open access respiratory sound database, with the best one reaching sensitivity and specificity values of 98% and 95%, respectively. Then, by changing one parameter in the design of the non-wheeze class, i.e., event duration, the best classifier only reached sensitivity and specificity values of 55% and 76%, respectively. These results demonstrate the importance of experimental design on the assessment of wheeze classification algorithms' performance.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑