arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2010.09822stat.ME
收藏

新模式更好吗?一个指标说是,但另一个说不是。我应该使用哪个指标?

Is the new model better? One metric says yes, but the other says no. Which metric do I use?

Qian M. Zhou, Zhe Lu, Russell J. Brooke, Melissa M Hudson, Yan Yuan

摘要:

增量价值(IncV)评估从现有风险模型到新模型的性能变化。这是决定一个新的风险模型是否比现有模型表现更好的关键因素之一。当不同的IncV指标相互矛盾时,就会出现问题。例如,与处方剂量模型相比,用于预测急性卵巢衰竭的卵巢剂量模型的受试者工作特征曲线下面积(AUC)略低,但精确-召回曲线下面积(AP)增加了48%。这种相互矛盾的结论的现象并不少见,它在医疗决策中造成了困境。在本文中,我们研究了两个IncV指标之间的分析联系和差异:IncV in AUC(IncV-AUC)和IncV in AP(IncV-AP)。此外,由于它们都是半适当的评分规则,我们比较它们与严格适当的评分规则:通过数值研究的比例化Brier评分(IncV-sBrS)的IncV。我们证明了IncV-AUC和IncV-AP都是将事件和非事件之间的风险评分分布分开的变化(从现有模型到新模型)的加权平均值。然而,IncV-AP为高风险组的变化分配了更重的权重,而IncV-AUC对变化的权重相同。在数值研究中,我们发现IncV-AP有一个很宽的范围,从负到正,但IncV-AUC的大小要小得多。此外,IncV-AP和IncV-sBrS高度一致,但IncV-AUC与IncV-sBrS和IncV-AP呈负相关,事件发生率较低。IncV-AUC和IncV-AP是三对中最不一致的,随着事件发生率的降低,它们的差异更加明显。

英文摘要:

Incremental value (IncV) evaluates the performance change from an existing risk model to a new model. It is one of the key considerations in deciding whether a new risk model performs better than the existing one. Problems arise when different IncV metrics contradict each other. For example, compared with a prescribed-dose model, an ovarian-dose model for predicting acute ovarian failure has a slightly lower area under the receiver operating characteristic curve (AUC) but increases the area under the precision-recall curve (AP) by 48%. This phenomenon of conflicting conclusions is not uncommon, and it creates a dilemma in medical decision making. In this article, we examine the analytical connections and differences between two IncV metrics: IncV in AUC (IncV-AUC) and IncV in AP (IncV-AP). Additionally, since they are both semi-proper scoring rules, we compare them with a strictly proper scoring rule: the IncV of the scaled Brier score (IncV-sBrS), via a numerical study. We demonstrate that both IncV-AUC and IncV-AP are weighted averages of the changes (from the existing model to the new one) in separating the risk score distributions between events and non-events. However, IncV-AP assigns heavier weights to the changes in the high-risk group, whereas IncV-AUC weights the changes equally. In the numerical study, we find that IncV-AP has a wide range, from negative to positive, but the size of IncV-AUC is much smaller. In addition, IncV-AP and IncV-sBr Sare highly consistent, but IncV-AUC is negatively correlated with IncV-sBrS and IncV-AP at a low event rate. IncV-AUC and IncV-AP are the least consistent among the three pairs, and their differences are more pronounced as the event rate decreases.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑