arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2009.11690physics.ins-dethep-ex
收藏

第一阶段Mu3e试验的技术设计

Technical design of the phase I Mu3e experiment

K. Arndt, H. Augustin, P. Baesso, N. Berger, F. Berg, C. Betancourt, D. Bortoletto, A. Bravar, K. Briggl, D. vom Bruch, A. Buonaura, F. Cadoux, C. Chavez Baraja… 展开作者

K. Arndt, H. Augustin, P. Baesso, N. Berger, F. Berg, C. Betancourt, D. Bortoletto, A. Bravar, K. Briggl, D. vom Bruch, A. Buonaura, F. Cadoux, C. Chavez Barajas, H. Chen, K. Clark, P. Cooke, S. Corrodi, A. Damyanova, Y. Demets, S. Dittmeier, P. Eckert, F. Ehrler, D. Fahrni, S. Gagneur, L. Gerritzen, J. Goldstein, D. Gottschalk, C. Grab, R. Gredig, A. Groves, J. Hammerich, U. Hartenstein, U. Hartmann, H. Hayward, A. Herkert, G. Hesketh, S. Hetzel, M. Hildebrandt, Z. Hodge, A. Hofer, Q. H. Huang, S. Hughes, L. Huth, D. M. Immig, T. Jones, M. Jones, H. -C. Kästli, M. Köppel, P. -R. Kettle, M. Kiehn, S. Kilani, H. Klingenmeyer, A. Knecht, A. Knight, B. Kotlinski, A. Kozlinskiy, R. Leys, G. Lockwood, A. Loreti, D. La Marra, M. Müller, B. Meier, F. Meier Aeschbacher, A. Meneses, K. Metodiev, A. Mtchedlishvili, S. Muley, Y. Munwes, L. O. S. Noehte, P. Owen, A. Papa, I. Paraskevas, I. Períc, A. -K. Perrevoort, R. Plackett, M. Pohl, S. Ritt, P. Robmann, N. Rompotis, T. Rudzki, G. Rutar, A. Schöning, R. Schimassek, H. -C. Schultz-Coulon, N. Serra, W. Shen, I. Shipsey, S. Shrestha, O. Steinkamp, A. Stoykov, U. Straumann, S. Streuli, K. Stumpf, N. Tata, J. Velthuis, L. Vigani, E. Vilella-Figueras, J. Vossebeld, R. Wallny, A. Wasili, F. Wauters, A. Weber, D. Wiedner, B. Windelband, T. Zhong

摘要:

Mu3e实验的目的是发现或排除在$10^{-16}$以上的分支分数处的轻子味违反衰变$μ\rightarrow eee$。第一阶段的实验使用现有的光束线在保罗谢勒研究所(PSI)的目的是达到$2\cdot 10^{-15}$的单事件灵敏度。我们提出了一个概述的各个方面的技术设计和预期性能的第一阶段Mu3e检测器。高达每秒$10^{8}$ μ子衰变的高速率以及衰变电子和正电子的低动量构成了一系列独特的挑战,我们使用基于高压单片有源像素传感器的超薄跟踪探测器与用于精确定时测量的反射纤维和瓦片相结合来解决这些挑战。

英文摘要:

The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ\rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2\cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the phase~I Mu3e detector. The high rate of up to $10^{8}$ muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑