arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2009.06434physics.app-phnucl-ex
收藏

便携式氢能系统用被动质子交换膜燃料电池的热中子照相

Thermal neutron radiography of a passive proton exchange membrane fuel cell for portable hydrogen energy systems

Antonio M. Chaparro, P. Ferreira-Aparicio, M. Antonia Folgado, Rico Hübscher, Carsten Lange, Norbert Weber

摘要:

利用热中子照相技术对一种低功耗便携式质子交换膜燃料电池(PEMFC)进行了研究。质子交换膜燃料电池在完全被动条件下运行,空气呼吸阴极和死端阳极分别提供静态环境空气和干燥氢气。圆柱形阴极板有利于水滴在阴极表面上的流动性和它们的消除。热中子图像显示了在电池处于垂直和水平位置的操作期间,即,其主平面分别平行于和垂直于重力场对准的情况下,液态水的积聚。极化曲线和阻抗谱显示细胞取向依赖的响应,可以与水的积累配置文件。在垂直位置中,阴极电极中较低的水含量有利于消除在阴极表面上滚动的水滴和自然对流的开始。因此,在垂直电池中改善了氧传输,其可以在环境条件下完全被动地操作数小时,提供高于100 mW/cm 2的稳定峰值功率密度。重力和自然对流在水平位置上的效果较差,由于氧气输送损失,导致峰值功率密度降低17%。如果上电极是阴极,则水平位置尤其不利,因为在产生少量水(5 mg/cm 2)之后阳极溢流导致电池故障。热中子照相和电池响应特性的组合信息解释了电池取向对便携式应用的全被动吸气式PEMFC性能的重要影响。

英文摘要:

A proton exchange membrane fuel cell (PEMFC) for low power and portable applications is studied with thermal neutron radiography. The PEMFC operates under full passive conditions, with an air-breathing cathode and a dead-end anode supplied with static ambient air and dry hydrogen, respectively. A columnar cathodic plate favors the mobility of water drops over the cathode surface and their elimination. Thermal neutron images show liquid water build up during operation with the cell in vertical and horizontal positions, i.e. with its main plane aligned parallel and perpendicular to the gravity field, respectively. Polarization curves and impedance spectroscopy show cell orientation dependent response that can be related with the water accumulation profiles. In vertical position, lower water contents in the cathode electrode is favored by the elimination of water drops rolling over the cathode surface and the onset of natural convection. As a consequence, oxygen transport is improved in the vertical cell, that can be operated full passive for hours under ambient conditions, providing steady peak power densities above 100 mW/cm2. Gravity and natural convection are less effective in horizontal position, leading to a 17% decrease in peak power density due to oxygen transport losses. The horizontal position is especially adverse if the upper electrode is the cathode, because of anode flooding causing cell failure after production of a small amount of water (5 mg/cm2). The combined information from thermal neutron radiography and cell response characteristics explains the important influence of cell orientation on the performance of a fully passive air-breathing PEMFC for portable applications.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑