arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2009.05074physics.app-phphysics.flu-dyn
收藏

用于性能评估和温度控制的Omnimagnet热模型

Thermal Model of an Omnimagnet for Performance Assessment and Temperature Control

Fateme Esmailie, Matthew S. Cavilla, Jake J. Abbott, Tim A. Ameel

摘要:

Omnimagnet是一种电磁设备,可以对医疗植入物和微型机器人等设备进行远程磁性操作。它是由三个正交嵌套的铁磁核心在中心。在欧姆内的电流导致焦耳热,导致在欧姆内的不期望的温度升高。如果温度超过电线绝缘层的熔点,则会发生设备故障。因此,研究Omnimagnet内的热传递是必要的,特别是为了最大限度地提高设备的性能。对于第一次,瞬态热传递模型,它结合了所有三种热传递模式,提出并验证了Omnimagnet与最大均方根误差等于8 ${\%}$(4 $^{\circ}$ C)的实验数据。这种瞬态模型在计算上并不昂贵。它相对容易应用于具有不同结构的Omnimagnets。该模型的准确性取决于输入数据的准确性。该代码被应用于计算在一个固定的输入电流的最大安全操作时间或在一个固定的时间间隔的最大安全输入电流。最大安全工作时间和最大安全输入电流取决于Omnimagnet的尺寸和结构以及所有Omnimagnet材料的最低熔点。参数的研究表明,增加对流传热过程中的冷却,并在加热与低输入电流,是一种有效的方法,以增加最大的操作时间的Omnimagnet.The热模型的状态空间方程的格式,可用于实时卡尔曼滤波电流控制器,以避免设备故障,由于过热。

英文摘要:

An Omnimagnet is an electromagnetic device that enables remote magnetic manipulation of devices such as medical implants and microrobots. It is comprised of three orthogonal nested solenoids with a ferromagnetic core at the center. Electrical current within the solenoids leads to Joule heating, resulting in undesired temperature increase within the Omnimagnet. If the temperature exceeds the melting point of the wire insulation, device failure will occur. Thus, a study of heat transfer within an Omnimagnet is a necessity, particularly to maximize the performance of the device. For the first time, a transient heat transfer model, that incorporates all three heat transfer modes, is proposed and validated with experimental data for an Omnimagnet with maximum root mean square error equal to 8${\%}$ (4$^{\circ}$C). This transient model is not computationally expensive. It is relatively easy to apply to Omnimagnets with different structures. The accuracy of this model depends on the accuracy of the input data. The code is applied to calculate the maximum safe operational time at a fixed input current or the maximum safe input current for a fixed time interval. The maximum safe operational time and maximum safe input current depend on size and structure of the Omnimagnet and the lowest melting point of all the Omnimagnet materials. A parametric study shows that increasing convective heat transfer during cooling, and during heating with low input currents, is an effective method to increase the maximum operational time of the Omnimagnet.The thermal model is also presented in a state-space equation format that can be used in a real-time Kalman filter current controller to avoid device failure due to excessive heating.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑