滞留物的定量和三维评估
Quantitative and Three-Dimensional Assessment of Holdup Material
摘要:
存放在处理设施的设备、输送管线和通风系统中的核材料通常称为滞留物。在这项工作中,我们建议使用一个阵列的检测器同轴的被检管道来测量滞留材料。该方法可实施到能够在各种曲率的表面和管道上爬行的自动化系统中,这将实现更快、更容易和更准确的持液量保障措施测量。我们首先证明,目前的滞留分析程序可能会导致一个不可忽略的偏差,在估计的特殊核材料的质量,由于简化的假设所引入的广义几何滞留(GGH)模型的沉积几何。新的方法包括成像的内部滞留材料的特征检测器阵列的响应和展开它从测量的光输出。我们的实验证明的原则包括三个碘化钠(铊)探测器周围的铝管含有两个铯-137(137 Cs)源。我们推导出的源分布内的管道,首先计算检测器的响应矩阵,使用的方法自适应的表面几何形状的对象包含测量的持液量材料。创建一个矩阵的探测器阵列的测量计数,然后我们继续解决一个逆问题,导致在一个准确定位的源位置和活动分布内的响应矩阵的空间分辨率。然后,我们开发了一个模拟模型的设想的实验装置,准确地描述了活动和位置的来源在2D。最后,我们将我们的模型扩展到系统的离散化三维模型上,包含36个检测器。对于四种不同源几何形状的3D模拟,模型精确地定位了3D中的源位置,而活性保留了± 5.32%的最大相对误差。
英文摘要:
Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array's response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137( 137Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array's measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix's spatial resolution. We then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of +-5.32%.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。