arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2008.09288hep-exnucl-exphysics.ins-det
收藏

用CANDLES-III低本底测量研究$^{48}$ Ca的无中微子双β衰变

Low background measurement in CANDLES-III for studying the neutrino-less double beta decay of $^{48}$Ca

S. Ajimura, W. M. Chan, K. Ichimura, T. Ishikawa, K. Kanagawa, B. T. Khai, T. Kishimoto, H. Kino, T. Maeda, K. Matsuoka, N. Nakatani, M. Nomachi, M. Saka, K. Se… 展开作者

S. Ajimura, W. M. Chan, K. Ichimura, T. Ishikawa, K. Kanagawa, B. T. Khai, T. Kishimoto, H. Kino, T. Maeda, K. Matsuoka, N. Nakatani, M. Nomachi, M. Saka, K. Seki, Y. Takemoto, Y. Takihira, D. Tanaka, M. Tanaka, K. Tetsuno, V. T. T. Trang, M. Tsuzuki, S. Umehara, K. Akutagawa, T. Batpurev, M. Doihara, S. Katagiri, E. Kinoshita, Y. Hirano, T. Iga, M. Ishikawa, G. Ito, H. Kakubata, K. K. Lee, X. Li, K. Mizukoshi, M. Moser, T. Ohata, M. Shokati, M. S. Soberi, T. Uehara, W. Wang, K. Yamamoto, K. Yasuda, S. Yoshida, N. Yotsunaga, T. Harada, H. Hiraoka, T. Hiyama, A. Hirota, Y. Ikeyama, A. Kawamura, Y. Kawashima, S. Maeda, K. Matsuoka, K. Nakajima, I. Ogawa, K. Ozawa, K. Shamoto, K. Shimizu, Y. Shinki, Y. Tamagawa, M. Tozawa, M. Yoshizawa, K. Fushimi, R. Hazama, P. Noithong, A. Rittirong, K. Suzuki, T. Iida

摘要:

我们建立了CANDLES-III系统来研究$^{48}$ Ca的无中微子双β(0 $νββ$)衰变。所提出的系统使用96 $_{2}$闪烁晶体(305 kg),其具有天然Ca($^{\rm nat.}$ Ca)同位素,其对应于350 μ g的$^{48}$ Ca。使用围绕CaF $_2$晶体的液体闪烁体的4 $π$有源屏蔽来拒绝外部背景。通过对信号脉冲波形的分析,可以有效地降低CaF $_2$晶体中放射性杂质引起的内本底。为了评价CANDLES-III探测器低本底测量的可行性,我们分析了在神冈地下获得的130.4天寿命的数据。利用Monte Carlo模拟,我们估算了CaF $_{2}$晶体中放射性杂质的本底率和环境中子引起的(n,$γ$)反应所产生的高能$γ$ -射线率。预期的背景速率与测量的速率非常一致,即,在0 $νββ$窗口中,约10起$^{-3}$事件/keV/年/($^{\rm nat.}$ Ca kg)。总之,通过将测量的能谱与背景模拟进行比较,适当地估计了背景候选者。使用这种测量方法,我们在低背景条件下使用具有Ca同位素的检测器进行了0 $νββ$衰变的第一次搜索,其中Ca不富集,规模为数百kg。的$^{48}$钙同位素具有很高的潜力,用于0 $νββ$衰变搜索,并预计将用于开发下一代探测器的高灵敏度测量。

英文摘要:

We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be reduced effectively through analysis of the signal pulse shape. We analyzed the data obtained in the Kamioka underground for a live-time of 130.4\,days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Using Monte Carlo simulations, we estimated the background rate from the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $γ$-rays caused by the (n, $γ$) reactions induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate, i.e., approximately 10$^{-3}$ events/keV/yr/(kg of $^{\rm nat.}$Ca), in the 0$νββ$ window. In conclusion, the background candidates were estimated properly by comparing the measured energy spectrum with the background simulations. With this measurement method, we performed the first search for 0$νββ$ decay in a low background condition using a detector with a Ca isotope, in which the Ca present was not enriched, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for use in 0$νββ$ decay search, and is expected to be useful for the development of a next-generation detector for highly sensitive measurements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑