液体Scintillator探测器瑞利散射长度的光谱测量方法
A Spectrometric Approach to Measuring the Rayleigh Scattering Length for Liquid Scintillator Detectors
摘要:
良好的光学透明性是液体闪烁体(LS)探测器的基本要求。表征液体闪烁体对其自身发射光的透明度是确定大体积探测器的总体灵敏度的关键参数。光在光学纯LS中的衰减由瑞利散射控制,这对LS的透明度造成了固有限制。本文提出了一种光谱法测量液体的波长依赖性散射长度的方法,通过应用Einstein-Smoluchowski理论测量散射光强度。测量了线性烷基苯(LAB)和EJ 309-碱(二异丙基萘,DIN)的散射长度,并在410至520 nm的波长范围内报告。标称LS发射的闪烁光的光谱峰约为430 nm,LAB和EJ-309碱的散射长度分别确定为27.9 +/- 2.3 m和6.1 +/- 0.6 m。
英文摘要:
Good optical transparency is a fundamental requirement of liquid scintillator (LS) detectors. Characterizing the transparency of a liquid scintillator to its own emitted light is a key parameter to determine the overall sensitivity of a large-volume detector. The attenuation of light in an optical-pure LS is dominated by Rayleigh scattering, which poses an intrinsic limit to the transparency of LS. This work presents a spectrometric approach of measuring the wavelength-dependent scattering length of liquids by applying the Einstein-Smoluchowski theory to a measurement of scattered light intensity. The scattering lengths of linear alkyl benzene (LAB) and EJ309-base (Di-isopropylnaphthalene, DIN) were measured and are reported in the wavelength range of 410 to 520 nm. The spectral peak of scintillation light emitted by a nominal LS is around 430 nm at which the scattering length for LAB and EJ-309-base was determined to be 27.9 +/- 2.3 m and 6.1 +/- 0.6 m respectively.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。