The perception of color is an important cognitive feature of the human brain. The variety of colors that impinge upon the human eye can trigger changes in brain activity which can be captured using electroencephalography (EEG). In this work, we have designed a multiclass classification model to detect the primary colors from the features of raw EEG signals. In contrast to previous research, our method employs spectral power features, statistical features as well as correlation features from the signal band power obtained from continuous Morlet wavelet transform instead of raw EEG, for the classification task. We have applied dimensionality reduction techniques such as Forward Feature Selection and Stacked Autoencoders to reduce the dimension of data eventually increasing the model's efficiency. Our proposed methodology using Forward Selection and Random Forest Classifier gave the best overall accuracy of 80.6\% for intra-subject classification. Our approach shows promise in developing techniques for cognitive tasks using color cues such as controlling Internet of Thing (IoT) devices by looking at primary colors for individuals with restricted motor abilities.
We present the first real-time sleep staging system that uses deep learning without the need for servers in a smartphone application for a wearable EEG. We employ real-time adaptation of a single channel Electroencephalography (EEG) to infer from a Time-Distributed 1-D Deep Convolutional Neural Network. Polysomnography (PSG)-the gold standard for sleep staging, requires a human scorer and is both complex and resource-intensive. Our work demonstrates an end-to-end on-smartphone pipeline that can infer sleep stages in just single 30-second epochs, with an overall accuracy of 83.5% on 20-fold cro…
Electroencephalogram (EEG) has been one of the common neuromonitoring modalities for real-world brain-computer interfaces (BCIs) because of its non-invasiveness, low cost, and high temporal resolution. Recently, light-weight and portable EEG wearable devices based on low-density montages have increased the convenience and usability of BCI applications. However, loss of EEG decoding performance is often inevitable due to reduced number of electrodes and coverage of scalp regions of a low-density EEG montage. To address this issue, we introduce knowledge distillation (KD), a learning mechanism d…
A limiting factor towards the wide routine use of wearables devices for continuous healthcare monitoring is their cumbersome and obtrusive nature. This is particularly true for electroencephalography (EEG) recordings, which require the placement of multiple electrodes in contact with the scalp. In this work, we propose to identify the optimal wearable EEG electrode set-up, in terms of minimal number of electrodes, comfortable location and performance, for EEG-based event detection and monitoring. By relying on the demonstrated power of autoencoder (AE) networks to learn latent representations …
School of Electrical and Computer Engineering, University of Tehran(德黑兰大学电气与计算机工程学院);Division of Intelligent Future Technologies, Malardalen University(马拉达伦大学智能未来技术系)
Long Short-Term Memory (LSTM) is widely used in various sequential applications. Complex LSTMs could be hardly deployed on wearable and resourced-limited devices due to the huge amount of computations and memory requirements. Binary LSTMs are introduced to cope with this problem, however, they lead to significant accuracy loss in some application such as EEG classification which is essential to be deployed in wearable devices. In this paper, we propose an efficient multi-level binarized LSTM which has significantly reduced computations whereas ensuring an accuracy pretty close to full precisio…
Prior-Guided Frequency-Calibrated Virtual EEG Channel Inference from Four Frontal Electrodes for Wearable EEG Augmentation
School of Biomedical Science and Engineering, South China University of Technology(生物医学工程学院,华南理工大学);School of Automation Science and Engineering, South China University of Technology(自动化科学与工程学院,华南理工大学)
ETH Zürich(苏黎世联邦理工学院);University of Bologna(博洛尼亚大学);University of Modena and Reggio Emilia(摩德纳-雷焦艾米利亚大学);Lausanne University Hospital (CHUV)(洛桑大学医院(CHUV))
We present the implementation of seizure detection algorithms based on a minimal number of EEG channels on a parallel ultra-low-power embedded platform. The analyses are based on the CHB-MIT dataset, and include explorations of different classification approaches (Support Vector Machines, Random Forest, Extra Trees, AdaBoost) and different pre/post-processing techniques to maximize sensitivity while guaranteeing no false alarms. We analyze global and subject-specific approaches, considering all 23-electrodes or only 4 temporal channels. For 8s window size and subject-specific approach, we repo…
Recording Brain Activity While Listening to Music Using Wearable EEG Devices Combined with Bidirectional Long Short-Term Memory Networks
School of Music, Jiangxi Normal University(江西师范大学音乐学院);School of Electronic Information, HuZhou College(湖州学院电子信息学院);San Francisco State University(旧金山州立大学)
University of Engineering and Technology, Taxila(塔克西拉工程技术大学);University of Central Florida(中佛罗里达大学)
Tactile enhanced multimedia is generated by synchronizing traditional multimedia clips, to generate hot and cold air effect, with an electric heater and a fan. This objective is to give viewers a more realistic and immersing feel of the multimedia content. The response to this enhanced multimedia content (mulsemedia) is evaluated in terms of the appreciation/emotion by using human brain signals. We observe and record electroencephalography (EEG) data using a commercially available four channel MUSE headband. A total of 21 participants voluntarily participated in this study for EEG recordings. …
Objective: With the rapid rise of wearable sleep monitoring devices with non-conventional electrode configurations, there is a need for automated algorithms that can perform sleep staging on configurations with small amounts of labeled data. Transfer learning has the ability to adapt neural network weights from a source modality (e.g. standard electrode configuration) to a new target modality (e.g. non-conventional electrode configuration). Methods: We propose feature matching, a new transfer learning strategy as an alternative to the commonly used finetuning approach. This method consists of …
Swiss Federal Institute of Technology Lausanne (EPFL)(洛桑联邦理工学院)
The healthcare landscape is moving from the reactive interventions focused on symptoms treatment to a more proactive prevention, from one-size-fits-all to personalized medicine, and from centralized to distributed paradigms. Wearable IoT devices and novel algorithms for continuous monitoring are essential components of this transition. Hyperdimensional (HD) computing is an emerging ML paradigm inspired by neuroscience research with various aspects interesting for IoT devices and biomedical applications. Here we explore the not yet addressed topic of optimal encoding of spatio-temporal data, su…
School of Engineering and Applied Science, Aston University(阿斯顿大学工程与应用科学学院)
This study suggests a new approach to EEG data classification by exploring the idea of using evolutionary computation to both select useful discriminative EEG features and optimise the topology of Artificial Neural Networks. An evolutionary algorithm is applied to select the most informative features from an initial set of 2550 EEG statistical features. Optimisation of a Multilayer Perceptron (MLP) is performed with an evolutionary approach before classification to estimate the best hyperparameters of the network. Deep learning and tuning with Long Short-Term Memory (LSTM) are also explored, a…
Université Paris-Saclay(巴黎萨克雷大学);Inria(法国国家信息与自动化研究所);CEA(法国原子能和替代能源委员会);InteraXon Inc.(InteraXon公司);Max Planck Institute for Human Cognitive and Brain Sciences(马克斯·普朗克人类认知与脑科学研究所)
Building machine learning models using EEG recorded outside of the laboratory setting requires methods robust to noisy data and randomly missing channels. This need is particularly great when working with sparse EEG montages (1-6 channels), often encountered in consumer-grade or mobile EEG devices. Neither classical machine learning models nor deep neural networks trained end-to-end on EEG are typically designed or tested for robustness to corruption, and especially to randomly missing channels. While some studies have proposed strategies for using data with missing channels, these approaches …
School of Electrical and Computer Engineering, University of Tehran(德黑兰大学电气与计算机工程学院);Division of Intelligent Future Technologies, Malardalen University(马拉达伦大学智能未来技术系)
Recurrent Neural Networks (RNN) are widely used for learning sequences in applications such as EEG classification. Complex RNNs could be hardly deployed on wearable devices due to their computation and memory-intensive processing patterns. Generally, reduction in precision leads much more efficiency and binarized RNNs are introduced as energy-efficient solutions. However, naive binarization methods lead to significant accuracy loss in EEG classification. In this paper, we propose a multi-level binarized LSTM, which significantly reduces computations whereas ensuring an accuracy pretty close to…
ETH Zürich(苏黎世联邦理工学院);University of Bologna(博洛尼亚大学);Huawei Technologies(华为技术有限公司)
Motor-Imagery Brain--Machine Interfaces (MI-BMIs)promise direct and accessible communication between human brains and machines by analyzing brain activities recorded with Electroencephalography (EEG). Latency, reliability, and privacy constraints make it unsuitable to offload the computation to the cloud. Practical use cases demand a wearable, battery-operated device with low average power consumption for long-term use. Recently, sophisticated algorithms, in particular deep learning models, have emerged for classifying EEG signals. While reaching outstanding accuracy, these models often exceed…
PHINN-EEG: Topological Time-Series Analysis of Dream-State EEG -- Dynamic Betti Curves for Dream Content Classification and Topology-Conditioned Neural Signal Synthesis
Driver vigilance estimation is an important task for transportation safety. Wearable and portable brain-computer interface devices provide a powerful means for real-time monitoring of the vigilance level of drivers to help with avoiding distracted or impaired driving. In this paper, we propose a novel multimodal architecture for in-vehicle vigilance estimation from Electroencephalogram and Electrooculogram. To enable the system to focus on the most salient parts of the learned multimodal representations, we propose an architecture composed of a capsule attention mechanism following a deep Long…
FetalSleepNet: A Transfer Learning Framework with Spectral Equalisation Domain Adaptation for Fetal Sleep Stage Classification
Department of Biomedical Informatics, Emory University(埃默里大学生物医学信息学系);Ritchie Centre, Hudson Institute of Medical Research(哈德逊医学研究所里奇中心);Department of Biomedical Engineering, Georgia Institute of Technology(佐治亚理工学院生物医学工程系);Department of Obstetrics and Gynaecology, Monash University(莫纳什大学妇产科学系);Department of Electrical and Computer Systems Engineering, Monash University(莫纳什大学电气与计算机系统工程系)
A Novel Data Augmentation Strategy for Robust Deep Learning Classification of Biomedical Time-Series Data: Application to ECG and EEG Analysis
Computer Science Department, College of Science, University of Zakho(扎赫大学科学学院计算机科学系);Department of Computer Science and Information Technology, The American University of Kurdistan(库尔德斯坦美国大学计算机科学与信息技术系);PRIME Lab, Scientific Research Center, University of Zakho(扎赫大学科学研究中心PRIME实验室)
University of Southern California(南加州大学);Rensselaer Polytechnic Institute(伦斯勒理工学院)
This paper focuses on analysis and design of time-varying complex networks having fractional order dynamics. These systems are key in modeling the complex dynamical processes arising in several natural and man made systems. Notably, examples include neurophysiological signals such as electroencephalogram (EEG) that captures the variation in potential fields, and blood oxygenation level dependent (BOLD) signal, which serves as a proxy for neuronal activity. Notwithstanding, the complex networks originated by locally measuring EEG and BOLD are often treated as isolated networks and do not captur…