Artificial Intelligence to Assist in Exclusion of Coronary Atherosclerosis during CCTA Evaluation of Chest-Pain in the Emergency Department: Preparing an Application for Real-World Use

Mayo Clinic(梅奥诊所);University of Iowa(爱荷华大学);Siemens Healthineers(西门子医疗);NVIDIA(英伟达)
Richard D. White, Barbaros S. Erdal, Mutlu Demirer, Vikash Gupta, Matthew T. Bigelow, Engin Dikici, Sema Candemir, Mauricio S. Galizia, Jessica L. Carpenter, Th… 展开作者

Richard D. White, Barbaros S. Erdal, Mutlu Demirer, Vikash Gupta, Matthew T. Bigelow, Engin Dikici, Sema Candemir, Mauricio S. Galizia, Jessica L. Carpenter, Thomas P. O Donnell, Abdul H. Halabi, Luciano M. Prevedello

英文摘要:

Coronary Computed Tomography Angiography (CCTA) evaluation of chest-pain patients in an Emergency Department (ED) is considered appropriate. While a negative CCTA interpretation supports direct patient discharge from an ED, labor-intensive analyses are required, with accuracy in jeopardy from distractions. We describe the development of an Artificial Intelligence (AI) algorithm and workflow for assisting interpreting physicians in CCTA screening for the absence of coronary atherosclerosis. The two-phase approach consisted of (1) Phase 1 - focused on the development and preliminary testing of an algorithm for vessel-centerline extraction classification in a balanced study population (n = 500 with 50% disease prevalence) derived by retrospective random case selection; and (2) Phase 2 - concerned with simulated-clinical Trialing of the developed algorithm on a per-case basis in a more real-world study population (n = 100 with 28% disease prevalence) from an ED chest-pain series. This allowed pre-deployment evaluation of the AI-based CCTA screening application which provides a vessel-by-vessel graphic display of algorithm inference results integrated into a clinically capable viewer. Algorithm performance evaluation used Area Under the Receiver-Operating-Characteristic Curve (AUC-ROC); confusion matrices reflected ground-truth vs AI determinations. The vessel-based algorithm demonstrated strong performance with AUC-ROC = 0.96. In both Phase 1 and Phase 2, independent of disease prevalence differences, negative predictive values at the case level were very high at 95%. The rate of completion of the algorithm workflow process (96% with inference results in 55-80 seconds) in Phase 2 depended on adequate image quality. There is potential for this AI application to assist in CCTA interpretation to help extricate atherosclerosis from chest-pain presentations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑