利用体外γ闪烁成像验证窦药物递送计算流体动力学(CFD)建模
Validation of Sinus Drug Delivery Computational Fluid Dynamics (CFD) Modeling with In Vitro Gamma Scintigraphy
摘要:
背景:慢性鼻窦炎(CRS)是一种流行性和破坏性疾病。药物治疗,包括鼻类固醇喷雾剂是主要的治疗方式。计算流体动力学(CFD)已被用于描述鼻窦气流和鼻内给药;然而,模拟方法的变化表明需要大规模CFD模型验证。方法:对3例功能性鼻内窥镜手术患者的术前、术后CT扫描资料,在Mimics(TM)中进行解剖重建。在18例病例中,使用Fluent(TM)的CFD方法进行流体分析和药物颗粒沉积建模。模型是3D打印的,并使用Tc 99标记的Nasacort(TM)进行体外研究。在叠加网格中对伽马射线照相信号和CFD建模的喷雾质量进行后处理并进行比较。使用重叠系数(OC)的统计分析评估了计算和实验分布之间的相似性,并采用Kendall的tau秩相关系数来检验独立性。结果如下:OC显示,CFD模型和实验结果之间的沉积百分比和网格轮廓高度一致(矢状、轴向和冠状网格的平均值[范围]分别为0.69 [0.57]、0.61 [0.49]和0.78 [0.44])。Kendall的tau值在分布之间显示出强一致性(平均0.73),除了一个模型中的单个冠状网格和另一个模型中的两个矢状网格之外,这些分布具有统计学显著性(p < 0.05)。结论:CFD建模与体外实验结果具有统计学一致性。该验证研究是同类研究中规模最大的研究之一,支持CFD在准确建模鼻喷雾给药和使用计算方法研究改善临床给药方法方面的适用性。
英文摘要:
Background: Chronic rhinosinusitis (CRS) is a prevalent and disruptive disease. Medical management including nasal steroid sprays is the primary treatment modality. Computational fluid dynamics (CFD) has been used to characterize sinonasal airflow and intranasal drug delivery; however, variation in simulation methods indicates a need for large scale CFD model validation. Methods: Anatomic reconstructions of pre and post-operative CT scans of 3 functional endoscopic sinus surgery patients were created in Mimics(TM). Fluid analysis and drug particle deposition modeling were conducted using CFD methods with Fluent(TM) in 18 cases. Models were 3D printed and in vitro studies were performed using Tc99-labeled Nasacort(TM). Gamma scintigraphy signals and CFD-modeled spray mass were post-processed in a superimposed grid and compared. Statistical analysis using overlap coefficients (OCs) evaluated similarities between computational and experimental distributions and Kendall's tau rank correlation coefficient was employed to test independence. Results: OCs revealed strong agreement in percent deposition and grid profiles between CFD models and experimental results (mean [range] for sagittal, axial, and coronal grids were 0.69 [0.57], 0.61 [0.49], and 0.78 [0.44], respectively). Kendall's tau values showed strong agreement (average 0.73) between distributions, which were statistically significant (p < 0.05) apart from a single coronal grid in one model and two sagittal grids of another. Conclusions: CFD modeling demonstrates statistical agreement with in vitro experimental results. This validation study is one of the largest of its kind and supports the applicability of CFD in accurately modeling nasal spray drug delivery and using computational methods to investigate means of improving clinical drug delivery.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。