基于PET-MRI的阿尔茨海默病tau蛋白扩散生物物理模型的校准
Calibration of Biophysical Models for tau-Protein Spreading in Alzheimer's Disease from PET-MRI
摘要:
错误折叠的tau蛋白(或简称为“tau”)的聚集体在阿尔茨海默病(AD)的进展中起着至关重要的作用,因为它们与细胞死亡和加速组织萎缩相关。纵向正电子发射断层扫描(PET)扫描可用于量化异常tau扩散的范围。这种基于PET的图像生物标志物是用于AD诊断和预后的有前景的技术。在这里,我们建议使用纵向PET扫描来校准器官尺度的生物物理数学模型,以提取特征性生长模式和tau的扩散。生物物理模型是一个反应-对流-扩散偏微分方程(PDE),只有两个标量未知参数,一个代表扩散(PDE的扩散部分),另一个代表tau的增长(PDE的反应部分)。平流项捕获组织萎缩,并从纵向磁共振成像(MRI)扫描的形态配准获得。我们描述的方法,提出了一个数值方案的生长和扩散参数的校准,使用合成数据进行灵敏度研究,我们进行了初步评估的临床扫描从ADNI数据集。我们研究这种模型校准是否是可能的,并调查这种校准的灵敏度,连续扫描之间的时间和萎缩的存在。我们的研究结果表明,尽管只使用两个校准参数,该模型可以重建临床扫描相当准确。我们发现,扫描之间的小时间间隔和背景噪声的存在造成了困难。我们重建的模型与数据拟合良好,但临床数据的研究也揭示了简单模型的缺点。有趣的是,这些参数显示出患者之间的显著差异,这表明这些参数可能是有用的生物标志物。
英文摘要:
Aggregates of misfolded tau proteins (or just 'tau' for brevity) play a crucial role in the progression of Alzheimer's disease (AD) as they correlate with cell death and accelerated tissue atrophy. Longitudinal positron emission tomography (PET) scans can be used quantify the extend of abnormal tau spread. Such PET-based image biomarkers are a promising technology for AD diagnosis and prognosis. Here, we propose to calibrate an organ-scale biophysical mathematical model using longitudinal PET scans to extract characteristic growth patterns and spreading of tau. The biophysical model is a reaction-advection-diffusion partial differential equation (PDE) with only two scalar unknown parameters, one representing the spreading (the diffusion part of the PDE) and the other one the growth of tau (the reaction part of the PDE). The advection term captures tissue atrophy and is obtained from diffeomorphic registration of longitudinal magnetic resonance imaging (MRI) scans. We describe the method, present a numerical scheme for the calibration of the growth and spreading parameters, perform a sensitivity study using synthetic data, and we perform a preliminary evaluation on clinical scans from the ADNI dataset. We study whether such model calibration is possible and investigate the sensitivity of such calibration to the time between consecutive scans and the presence of atrophy. Our findings show that despite using only two calibration parameters, the model can reconstruct clinical scans quite accurately. We discovered that small time intervals between scans and the presence of background noise create difficulties. Our reconstructed model fits the data well, yet the study on clinical data also reveals shortcomings of the simplistic model. Interestingly, the parameters show significant variability across patients, an indication that these parameters could be useful biomarkers.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。