采用显著强度变化光源的基线不灵敏吸收光谱的倒谱分析

Cepstral Analysis for Baseline-Insensitive Absorption Spectroscopy Using Light Sources with Pronounced Intensity Variations

Christopher S. Goldenstein, Garrett C. Mathews, Ryan K. Cole, Amanda S. Makowiecki, Gregory B. Rieker

摘要:

本文介绍了一种数据处理技术,它提高了吸收光谱测量的准确性和精度,通过分离分子吸光度信号的基线光强度(Io)的误差,使用倒谱分析。最近,倒谱分析已与传统的吸收光谱仪一起使用,以创建时域分子自由感应衰减(m-FID)信号的修改形式,该信号可以独立于Io进行分析。然而,当基线强度和分子响应在时域中没有很好地分离时,分子特征的独立分析是不可能的,这在使用注入电流调谐激光器(例如,量子级联激光器)和具有显著强度调谐的其它光源。相比之下,这里提出的方法适用于所有光源,因为它通过在时域中将模拟的m-FID信号最小二乘拟合到测量的m-FID信号来确定气体特性。这种方法是不敏感的误差估计Io随光频率变化缓慢,因此,在时域中迅速衰减。这种方法提供的好处是通过扫描波长直接吸收测量与分布反馈(DFB)量子级联激光器(QCL)获得证明。DFB QCL的波长在1 kHz下扫描CO的P(0,20)和P(1,14)吸收跃迁,以测量气体温度和CO浓度。使用新的基于m-FID的方法和两种依赖于推断光谱拟合例程内的基线误差的传统方法来处理所测量的光谱。基于m-FID的方法在所有情况下都表现出优越的准确性,并且测量精度比使用传统方法提供的测量精度小1.5至10倍。

英文摘要:

This manuscript presents a data-processing technique which improves the accuracy and precision of absorption-spectroscopy measurements by isolating the molecular absorbance signal from errors in the baseline light intensity (Io) using cepstral analysis. Recently, cepstral analysis has been used with traditional absorption spectrometers to create a modified form of the time-domain molecular free-induction decay (m-FID) signal which can be analyzed independently from Io. However, independent analysis of the molecular signature is not possible when the baseline intensity and molecular response do not separate well in the time domain, which is typical when using injection-current-tuned lasers (e.g., quantum cascade lasers) and other light sources with pronounced intensity tuning. In contrast, the method presented here is applicable to all light sources since it determines gas properties by least-squares fitting a simulated m-FID signal to the measured m-FID signal in the time domain. This method is insensitive to errors in the estimated Io which vary slowly with optical frequency and, therefore, decay rapidly in the time domain. The benefits provided by this method are demonstrated via scanned-wavelength direct-absorption measurements acquired with a distributed-feedback (DFB) quantum-cascade laser (QCL). The wavelength of a DFB QCL was scanned across CO's P(0,20) and P(1,14) absorption transitions at 1 kHz to measure the gas temperature and concentration of CO. Measurements were acquired in a gas cell and in an ethylene-air flame at 1 atm. The measured spectra were processed using the new m-FID-based method and two traditional methods which rely on inferring the baseline error within the spectral-fitting routine. The m-FID-based method demonstrated superior accuracy in all cases and a measurement precision that was 1.5 to 10 times smaller than that provided using traditional methods.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑