arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2005.10616physics.med-ph
收藏

栓系胶囊正面光学相干断层扫描用于非镇静患者Barrett食管成像

Tethered capsule en face optical coherence tomography for imaging Barrett's esophagus in unsedated patients

Kaicheng Liang, Osman O. Ahsen, Annalee Murphy, Jason Zhang, Tan H. Nguyen, Benjamin M. Potsaid, Marisa Figueiredo, Qin Huang, Hiroshi Mashimo, James G. Fujimoto

摘要:

在内窥镜检查室外的护理点检测Barrett食管(BE)可能会改善筛查途径并降低食管腺癌死亡率。栓系胶囊光学相干断层扫描(OCT)可以对食管粘膜进行体积成像,并检测未服用镇静剂患者的BE。我们研究了未使用镇静剂的患者中的超高速栓系胶囊、扫频源OCT(SS-OCT),改进了器械设计,开发了手术技术,测量了胶囊接触和纵向回撤不均匀性如何影响覆盖范围,并评估了患者耐受性。在内窥镜监测/治疗前,对16例患者进行了OCT。未服用镇静剂的患者用小口水吞下胶囊,通过收回系绳对食管进行成像。超高速SS-OCT以1,000,000 A扫描/秒的速度在10秒内对约40 cm $^2$食管区域进行成像,横向分辨率为30 um,轴向分辨率为8 um。9名患者患有非异型增生BE,3名患者患有消融治疗初治肿瘤,4名患者因异型增生病史接受过消融术。胶囊手术耐受性良好。超高速SS-OCT能够生成横截面和表面下的正面图像。BE可以在横截面和正面图像中快速识别,而胃食管交界处(GEJ)的评估需要表面下的正面视图。长段BE和滑动型食管裂孔疝的胶囊食管接触更差,短段BE的纵向图像覆盖更差。报告了发育不良的OCT候选特征。超高速栓系胶囊SS-OCT能够对大面积粘膜特征进行正面和横断面成像。器械和手术优化改善了成像性能。BE区域可以很容易识别,但有限的胶囊接触和纵向图像覆盖范围可能会产生采样误差。

英文摘要:

Detection of Barrett's esophagus (BE) at points of care outside the endoscopy suite may improve screening access and reduce esophageal adenocarcinoma mortality. Tethered capsule optical coherence tomography (OCT) can volumetrically image esophageal mucosa and detect BE in unsedated patients. We investigated ultrahigh-speed tethered capsule, swept-source OCT (SS-OCT) in unsedated patients, improved device design, developed procedural techniques, measured how capsule contact and longitudinal pullback non-uniformity affect coverage, and assessed patient toleration. OCT was performed in 16 patients prior to endoscopic surveillance/treatment. Unsedated patients swallowed the capsule with small sips of water and the esophagus imaged by retracting the tether. Ultrahigh-speed SS-OCT at 1,000,000 A-scans/second imaged ~40cm$^2$ esophageal areas in 10 seconds with 30um transverse and 8um axial resolution. Nine patients had non-dysplastic BE, 3 had ablative treatment-naive neoplasia, and 4 had prior ablation for history of dysplasia. The capsule procedure was well tolerated. Ultrahigh-speed SS-OCT enabled the generation of cross-sectional and sub-surface en face images. BE could be rapidly identified in cross-sectional and en face images, while assessment of the gastro-esophageal junction (GEJ) required subsurface en face views. Capsule esophageal contact was worse in long-segment BE and sliding hiatal hernia, and longitudinal image coverage was worse in short-segment BE. OCT candidate features of dysplasia are reported. Ultrahigh-speed tethered capsule SS-OCT enabled en face and cross-sectional imaging of mucosal features over wide areas. Device and procedure optimization led to improved imaging performance. Areas of BE could be readily identified, but limited capsule contact and longitudinal image coverage can yield sampling errors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑