Diagnosis of high impedance fault (HIF) is a challenge for nowadays distribution network protections. The fault current of a HIF is much lower than that of a normal load, and fault feature is significantly affected by fault scenarios. A detection and feeder identification algorithm for HIFs is proposed in this paper, based on the high-resolution and synchronous waveform data. In the algorithm, an interval slope is defined to describe the waveform distortions, which guarantees a uniform feature description under various HIF nonlinearities and noise interferences. For three typical types of network neutrals, i.e.,isolated neutral, resonant neutral, and low-resistor-earthed neutral, differences of the distorted components between the zero-sequence currents of healthy and faulty feeders are mathematically deduced, respectively. As a result, the proposed criterion, which is based on the distortion relationships between zero-sequence currents of feeders and the zero-sequence voltage at the substation, is theoretically supported. 28 HIFs grounded to various materials are tested in a 10kV distribution networkwith three neutral types, and are utilized to verify the effectiveness of the proposed algorithm.
Solar distribution feeders are commonly used in solar farms that are integrated into distribution substations. In this paper, we focus on a real-world solar distribution feeder and conduct an event-based analysis by using micro-PMU measurements. The solar distribution feeder of interest is a behind-the-meter solar farm with a generation capacity of over 4 MW that has about 200 low-voltage distributed photovoltaic (PV) inverters. The event-based analysis in this study seeks to address the following practical matters. First, we conduct event detection by using an unsupervised machine learning ap…
Motivated by increasing penetration of distributed generators (DGs) and fast development of micro-phasor measurement units (μPMUs), this paper proposes a novel graph-based faulted line identification algorithm using a limited number of μPMUs in distribution networks. The core of the proposed method is to apply advanced distribution system state estimation (DSSE) techniques integrating μPMU data to the fault location. We propose a distributed DSSE algorithm to efficiently restrict the searching region for the fault source in the feeder between two adjacent μPMUs. Based on the graph model of the…
High impedance faults (HIFs) in distribution grids may cause wildfires and threaten human lives. Conventional protection relays at substations fail to detect more than 10\% HIFs since over-currents are low and the signatures of HIFs are local. With more $μ$PMU being installed in the distribution system, high-resolution $μ$PMU datasets provide the opportunity of detecting HIFs from multiple points. Still, the main obstacle in applying the $μ$PMU datasets is the lack of labels. To address this issue, we construct a physics-informed convolutional auto-encoder (PICAE) to detect HIFs without labele…
In this paper, a neural network predictive controller is proposed to regulate the active and the reactive power delivered to the grid generated by a three-phase virtual inertia-based inverter. The concept of the conventional virtual synchronous generator (VSG) is discussed, and it is shown that when the inverter is connected to non-inductive grids, the conventional PI-based VSGs are unable to perform acceptable tracking. The concept of the neural network predictive controller is also discussed to replace the traditional VSGs. This replacement enables inverters to perform in both inductive and …
Reducing the current is a common method to ensure the synchronous stability of a modular multilevel converter (MMC) when there is a short-circuit fault at its AC side. However, the uncertainty of the fault location of the AC system leads to a significant difference in the maximum allowable stable operating current during the fault. This paper proposes an adaptive MMC fault-current control method using local phasor measurement unit (PMU) measurements. Based on the estimated Thevenin equivalent (TE) parameters of the system, the current can be directly calculated to ensure the maximum output pow…
Missouri University of Science and Technology(密苏里科技大学)
In this paper a neural network heuristic dynamic programing (HDP) is used for optimal control of the virtual inertia based control of grid connected three phase inverters. It is shown that the conventional virtual inertia controllers are not suited for non inductive grids. A neural network based controller is proposed to adapt to any impedance angle. Applying an adaptive dynamic programming controller instead of a supervised controlled method enables the system to adjust itself to different conditions. The proposed HDP consists of two subnetworks, critic network and action network. These netwo…
Network reconfiguration (NR) has attracted much attention due to its ability to convert conventional distribution networks (DNs) into self-healing grids. This paper proposes a new strategy for real-time voltage regulation (VR) in a reconfigurable DN, whereby optimal feedforward control of synchronous and inverter-based distributed generators (DGs) is achieved in coordination with the operation of feeder line switches (SWs). This enables preemptive compensation of upcoming deviations in DN voltages caused by NR-aided load restoration. A robust optimization problem is formulated using a dynamic …