The Penning trap has been investigated as the basis of a small nuclear fusion reactor using a superconducting solenoid magnet. To extend this investigation, we designed, constructed, and evaluated a permanent magnet Penning trap. The device consists of a solenoid formed from an annular array of neodymium bar magnets between two iron pole pieces designed to give a uniform magnetic field in the central volume of the device. Critical to achieving the uniform solenoidal field is an iron equatorial ring supported within the annular array of magnets. A nonmagnetic titanium Penning trap with hyperbolic surfaces designed to produce a spherical potential well was mounted inside the permanent magnet assembly. The trap was fitted with a nonmagnetic hairpin filament electron source and demonstrated to produce electron trapping at the theoretically predicted magnetic fields and trap potentials. Trap potentials achievable were limited by electrical breakdown within the trap operating in constant potential mode. Efforts were made to extend the trap potentials using pulsed anode voltages, but nuclear fusion in a Penning trap has not yet been demonstrated. The design and construction of the permanent magnet solenoid and nonmagnetic trap are presented here as potentially useful also in other studies.
A newly constructed apparatus at the National Institute of Standards and Technology (NIST) is designed for the isolation, manipulation, and study of highly charged ions. Highly charged ions are produced in the NIST electron-beam ion trap (EBIT), extracted through a beamline that selects a single mass/charge species, then captured in a compact Penning trap. The magnetic field of the trap is generated by cylindrical NdFeB permanent magnets integrated into its electrodes. In a room-temperature prototype trap with a single NdFeB magnet, species including Ne10+ and N7+ were confined with storage ti…
Penning traps are made extremely compact by embedding rare-earth permanent magnets in the electrode structure. Axially-oriented NdFeB magnets are used in unitary architectures that couple the electric and magnetic components into an integrated structure. We have constructed a two- magnet Penning trap with radial access to enable the use of laser or atomic beams, as well as the collection of light. An experimental apparatus equipped with ion optics is installed at the NIST electron beam ion trap (EBIT) facility, constrained to fit within 1 meter at the end of a horizontal beamline for transport…
Cyclotron-Frequency Stability via Single-Ion Fluorescence in a Penning Trap with a Cryogen-Free Superconducting Magnet
Universidad de Granada(格拉纳达大学);Johannes Gutenberg-Universität Mainz(约翰内斯·古腾堡美因茨大学);Helmholtz-Institut Mainz(美因茨亥姆霍兹研究所);GSI Helmholtzzentrum für Schwerionenforschung GmbH(GSI重离子研究中心有限公司)
Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influence…
For magnetic field calculations, cylindrical permanent magnets are often approximated as ideal, azimuthally symmetric solenoids. Despite the frequent usage of this approximation, research papers demonstrating the validity and limitations of this approach are scarcely available. In this paper, the experimentally derived magnetic field of a cylindrical permanent magnet is compared with the analytically calculated magnetic field of an ideal solenoid. An experimental setup for measuring the magnetic field distribution is demonstrated and employed for gathering the data. The proposed setup allows t…
Permanent magnets with yokes are widely used in the watt and joule balances to measure the Planck constant for the forthcoming redefinition of the unit of mass, the kilogram. Recently, a permanent magnet system has been in consideration for a further practice of NIM-2, the generalized joule balance. In this paper, an analytical model to design the permanent magnet system is presented. The presented model can be solved to obtain the preliminary parameters and then is used as guidance for FEA software to optimize the parameters of such magnetic system. As an instance for the application of the d…
A novel frequency modulated MEMS magnetometer is presented. The new device is inspired by the magnetic force microscopy technique, it combines standard MEMS technology with magnetic elements to obtain a magnetometer with potential for low power consumption and high performance. The analytical model and the characterization of the first proof-concept device are presented.
Topology optimization of permanent magnet systems consisting of permanent magnets, high permeability iron and air is presented. An implementation of topology optimization for magnetostatics is discussed and three examples are considered. First, the Halbach cylinder is topology optimized with iron and an increase of 15% in magnetic efficiency is shown, albeit with an increase of 3.8 pp. in field inhomogeneity - a value compared to the inhomogeneity in a 16 segmented Halbach cylinder. Following this a topology optimized structure to concentrate a homogeneous field is shown to increase the magnit…
At Central Michigan University we are developing a high-precision Penning trap mass spectrometer (CHIP-TRAP)that will focus on measurements with long-lived radioactive isotopes. CHIP-TRAP will consist of a pair of hyperbolic precision-measurement Penning traps, and a cylindrical capture/filter trap in a 12 T magnetic field. Ions will be produced by external ion sources, including a laser ablation source, and transported to the capture trap at low energies enabling ions of a given m=q ratio to be selected via their time-of-flight. In the capture trap, contaminant ions will be removed with a mas…
This review is concerned with a detailed analysis of some of the technical problems which arise in the application of the Penning trap method to the experimental study of neutron $β$ -decay,a technique which was first successfully tested on the low-flux swimming-pool reactor LIDO (capture flux =3$\cdot 10^6$cm$^(-2)$s$^(-1)$) at AERE Harwell in the 1970's. It does not discuss the scientific merits or demerits of these studies. Of particular importance are the trapping and release of neutron decay protons, and the influence of magnetic mirror effects and radial drifting on the trapped particles…
A permanent magnet assembly in which the flux density can be altered by a mechanical operation is often significantly smaller than comparable electromagnets and also requires no electrical power to operate. In this paper five permanent magnet designs in which the magnetic flux density can be altered are analyzed using numerical simulations, and compared based on the generated magnetic flux density in a sample volume and the amount of magnet material used. The designs are the concentric Halbach cylinder, the two half Halbach cylinders, the two linear Halbach arrays and the four and six rod mang…
For two decades, NdFeB based magnets have been a critical component in a range of electrical devices engaged in energy production and conversion. The magnet shape and the internal microstructure of the selected NdFeB grade govern their efficiency and size. However, stricter requirements on device efficiency call for better performing magnets preferably with novel functionality not achievable today. Here we use 3D metal printing by Selective Laser Melting to fabricate dense net shape permanent magnets based on NdFeB that exhibit high magnetic performance. Evidence is provided that the internal …
The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the fluctuations by at least one order of magnitude downto dT=+/-5mK…
Static magnetic field gradients superimposed on the electromagnetic trapping potential of a Penning trap can be used to implement laser-less spin-motion couplings that allow the realization of elementary quantum logic operations in the radio-frequency regime. An important scenario of practical interest is the application to $g$-factor measurements with single (anti-)protons to test the fundamental charge, parity, time reversal (CPT) invariance as pursued in the BASE collaboration [Smorra et al., Eur. Phys. J. Spec. Top. 224, 3055-3108 (2015), Smorra et al., Nature 550, 371-374 (2017), Schneide…
The KATRIN experiment is going to search for the mass of the electron antineutrino down to 0.2 eV/c^2. In order to reach this sensitivity the background rate has to be understood and minimised to 0.01 counts per second. One of the background sources is the unavoidable Penning trap for electrons due to the combination of the electric and magnetic fields between the pre- and the main spectrometer at KATRIN. In this article we will show that by sweeping a conducting wire periodically through such a particle trap stored particles can be removed, an ongoing discharge in the trap can be stopped, and…
The Penning-trap electronic-detection technique that offers the precision and sensitivity requested in mass spectrometry for fundamental studies in nuclear and particle physics has not been proven yet to be universal. This has motivated the construction of a Penning-trap facility aiming at the implementation of a novel detection method, consisting in measuring motional frequencies of singly-charged trapped ions in strong magnetic fields, through the fluorescence photons from the 4s$^2$S$_{1/2}\rightarrow $4p$^2$P$_{1/2}$ atomic transition in $^{40}$Ca$^+$. The key element of this facility is a…
In this article, the dynamics of an unbalanced two-ion crystal comprising the 'target' and the 'sensor' ions confined in a Penning trap has been studied. First, the low amplitude regime is addressed. In this regime, the overall potential including the Coulomb repulsion between the ions can be considered harmonic and the axial, magnetron and reduced-cyclotron modes split up into the so-called 'stretch' and 'common' modes, that are generalizations of the well-known 'breathing' and 'center-of-mass' motions of a balanced crystal made of two ions. By measuring the frequency modes of the crystal and…
A design for a permanent magnet system is proposed that generates spatially homogeneous, constant magnetic field gradients, thus creating conditions suitable for MRI without gradient coils and amplifiers. This is achieved by superimposing a weak Halbach quadrupole on a strong Halbach dipole. Rotation of either the quadrupole or the entire magnet assembly can be used to generate 2D images via filtered back-projection. Additionally, the mutual rotation of two quadrupoles can be used to scale the resulting gradient. If both gradients have identical strength the gradient can even be made to vanish…
Ferromagnetic-ferroelectric composites have attracted interests in recent years for use as magnetic field sensors. The sensing is based on magneto-electric (ME) coupling between the electric and magnetic subsystems and is mediated by mechanical strain. Such sensors for AC magnetic fields require a bias magnetic field to achieve pT-sensitivity. Here we discuss measurements and theory for a novel passive, AC magnetic sensor that does not require a bias magnetic field and is based on a PZT bimorph with a permanent magnet proof mass. Mechanical strain on the PZT bimorph in this case is produced by…
Magnetic fields are a standard tool in the toolbox of every physicist, and are required for the characterization of materials, as well as the polarization of spins in nuclear magnetic resonance or electron paramagnetic resonance experiments. Quite often a static magnetic field of sufficiently large, but fixed magnitude is suitable for these tasks. Here we present a permanent magnet assembly that can achieve magnetic field strengths of up to 1.5T over an air gap length of 7mm. The assembly is based on a Halbach array of neodymium (NdFeB) magnets, with the inclusion of the soft magnetic material…
We present the design, construction and characterization of an experimental system capable of supporting a broad class of quantum simulation experiments with hundreds of spin qubits using Be-9 ions in a Penning trap. This article provides a detailed overview of the core optical and trapping subsystems, and their integration. We begin with a description of a dual-trap design separating loading and experimental zones and associated vacuum infrastructure design. The experimental-zone trap electrodes are designed for wide-angle optical access (e.g. for lasers used to engineer spin-motional couplin…
Watt balances are used to measure the Planck constant and will be used in the future to realize mass at the kilogram level. They increasingly rely on permanent magnet systems to generate the magnetic flux. It has been known that the weighing current might effect the magnetization state of the permanent magnetic system used in these systems causing a systematic bias that can lead to an error in the result if not accounted for. In this article a simple model explaining the effect of the weighing current on the yoke of the magnet is developed. This model leads to a nonlinear dependence of the mag…
We report on a 3/8" OD x 1/4" ID x 3/8" long NdFeB assembly of 1/16" thick annulars boasting half the 1/100 far field transverse decay distance compared to an ID Helholtz-spaced pair of similar annulars; and greater than 50% of ID collimated better than 1/1000. The device is applied to a He-3,-4 laser spectroscopy experiment.
Portable low-cost MRI systems have the potential to enable point-of-care and timely MRI diagnosis, and to make this imaging modality available to routine scans and to underdeveloped areas. With simplicity, no maintenance, no power consumption, and low cost, permanent magnets or arrays are attractive to use as a source of magnetic field to realize portability and low cost for a scanners. However, when taking the Fourier imaging approach and using linear gradient fields, homogeneous fields are required, thus either a bulky magnet is needed, or the imaging volume is too small to image an organ if…
We describe the design, assembly, and testing of a magnet intended to deflect beams of paramagnetic nanoclusters, molecules, and atoms. It is energized by high-grade permanent neodymium magnets. This offers a convenient option in terms of cost, portability, and scalability of the construction, while providing field and gradient values (1.1 T, 330 T/m) which are fully comparable with commonly used electromagnet deflectors.
Halbach magnets are a source of homogeneous magnetic field in an enclosed volume while keeping stray fields at a minimum. Here, we present the design, construction, and characterization for a 10 cm inner diameter double Halbach ring providing a homogeneous (<100 ppm over 1 x 1 x 0.5 cm3) magnetic field of around 105 mT, which will be used for a diamond based microwave-free widefield imaging setup. The final characterization is performed with a novel fiberized diamond-based sensor on a 3D translation stage documenting the high homogeneity of the constructed Halbach array and its suitability for…