容性反馈晶体管放大器频率响应分析及设计准则

Frequency Response Analysis and Design Rules for Capacitive Feedback Transimpedance Amplifier

Jung-hoon Noh

摘要:

精密仪器系统,如光接收器和其他电流输出测量系统,通常包含跨谐放大器(TIA)。常用的电阻反馈TIA(RF-TIA)在实际应用中存在一个缺点:在高速应用中,系统带宽受到反馈电阻及其寄生电容的限制。为了克服这个缺点,可以使用电容反馈TIA(CF-TIA)。CF-TIA的增益和带宽性能在理论上与RF-TIA相当。虽然CF-TIA已经在以前的研究中被引入,以降低热噪声和解决高电阻与CMOS技术集成的困难,但过去的分析还不够深入。本研究的最终目的是提供设计师在这一领域有帮助的设计规则和分析工具。特别是,传递函数模型,关键的设计参数,和稳定性分析。此外,一个新的CF-TIA配置涉及一个简化的积分器直流反馈环,它可以部署为一个单级,而不是传统的两级拓扑结构。虽然本研究中考虑的应用是高速传感器测量和具有高输入电容的设备,例如激光位置检测器,但本文获得的分析结果也适用于各种其他应用,例如新兴的生物传感器和光学通信系统。

英文摘要:

Precision instrumentation systems, such as optical receivers and other current-output measurement systems, often contain a transimpedance amplifier (TIA). The commonly used resistive feedback TIA (RF-TIA) has a drawback in its practical implementation; the system bandwidth is limited by the feedback resistor and its parasitic capacitance in high-speed applications. To overcome this drawback, a capacitive feedback TIA (CF-TIA) can be used. The gain and bandwidth performance of the CF-TIA are theoretically equivalent to those of the RF-TIA. Although CF-TIA has been introduced in previous studies for reducing thermal noise and addressing the difficulty in integrating a high resistance with CMOS technology, past analyses have not been in sufficient depth. The ultimate goal of this study is providing designers in this field with helpful design rules and analytical tools. In particular, a transfer function model, the critical design parameters, and a stability analysis are presented. Furthermore, a new CF-TIA configuration involving a simplified integrator DC feedback loop is introduced, which can be deployed as a single stage rather than the conventional two-stage topology. While the applications considered in this study were high-speed sensor measurements and devices with a high input capacitance, such as a laser position detector, the analytical results obtained herein also applicable to a variety of other applications such as emerging biosensors and optical communication system.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑