Wrist-worn smart devices are providing increased insights into human health, behaviour and performance through sophisticated analytics. However, battery life, device cost and sensor performance in the face of movement-related artefact present challenges which must be further addressed to see effective applications and wider adoption through commoditisation of the technology. We address these challenges by demonstrating, through using a simple optical measurement, photoplethysmography (PPG) used conventionally for heart rate detection in wrist-worn sensors, that we can provide improved heart rate and human activity recognition (HAR) simultaneously at low sample rates, without an inertial measurement unit. This simplifies hardware design and reduces costs and power budgets. We apply two deep learning pipelines, one for human activity recognition and one for heart rate estimation. HAR is achieved through the application of a visual classification approach, capable of robust performance at low sample rates. Here, transfer learning is leveraged to retrain a convolutional neural network (CNN) to distinguish characteristics of the PPG during different human activities. For heart rate estimation we use a CNN adopted for regression which maps noisy optical signals to heart rate estimates. In both cases, comparisons are made with leading conventional approaches. Our results demonstrate a low sampling frequency can achieve good performance without significant degradation of accuracy. 5 Hz and 10 Hz were shown to have 80.2% and 83.0% classification accuracy for HAR respectively. These same sampling frequencies also yielded a robust heart rate estimation which was comparative with that achieved at the more energy-intensive rate of 256 Hz.
Peripheral blood oxygen saturation Sp02 is a vital measure in healthcare. Modern off-the-shelf wrist-worn devices, such as the Apple Watch, FitBit, and Samsung Gear, have an onboard sensor called a pulse oximeter. While pulse oximeters are capable of measuring both Sp02 and heart rate, current wrist-worn devices use them only to determine heart rate, as Sp02 measurements collected from the wrist are believed to be inaccurate. Enabling oxygen saturation monitoring on wearable devices would make these devices tremendously more useful for health monitoring and open up new avenues of research. To …
Cardiopulmonary resuscitation (CPR) is one of the most critical emergency interventions for sudden cardiac arrest. In this paper, a robust sinusoidal model-fitting method based on a Evolution Strategy inspired algorithm for CPR quality parameters -- naming chest compression frequency and depth -- as measured by an inertial measurement unit (IMU) attached to the wrist is presented. The proposed approach will allow bystanders to improve CPR as part of a continuous closed-loop support system once integrated into a smartphone or smartwatch application. By evaluating the model's precision with data…
In recent years, there have been a surge in ubiquitous technologies such as smartwatches and fitness trackers that can track the human physical activities effortlessly. These devices have enabled common citizens to track their physical fitness and encourage them to lead a healthy lifestyle. Among various exercises, walking and running are the most common ones people do in everyday life, either through commute, exercise, or doing household chores. If done at the right intensity, walking and running are sufficient enough to help individual reach the fitness and weight-loss goals. Therefore, it i…
The technological advancement in wireless health monitoring through the direct contact of the skin allows the development of light-weight wrist-worn wearable devices to be equipped with different sensors such as photoplethysmography (PPG) sensors. However, the motion artifact (MA) is possible to occur during daily activities. In this study, we attempted to perform a post-calibration of the heart rate (HR) estimation during the three possible states of average daily activity (resting, \textcolor{red}{laying down}, and intense treadmill activity states) in 29 participants (130 minutes/person) on…
Stress is a physiological state that hampers mental health and has serious consequences to physical health. Moreover, the COVID-19 pandemic has increased stress levels among people across the globe. Therefore, continuous monitoring and detection of stress are necessary. The recent advances in wearable devices have allowed the monitoring of several physiological signals related to stress. Among them, wrist-worn wearable devices like smartwatches are most popular due to their convenient usage. And the photoplethysmography (PPG) sensor is the most prevalent sensor in almost all consumer-grade wri…
University of Florida(佛罗里达大学);Johns Hopkins University(约翰斯·霍普金斯大学);Wake Forest University(维克森林大学)
Wrist accelerometers for assessing hallmark measures of physical activity (PA) are rapidly growing with the advent of smartwatch technology. Given the growing popularity of wrist-worn accelerometers, there needs to be a rigorous evaluation for recognizing (PA) type and estimating energy expenditure (EE) across the lifespan. Participants (66% women, aged 20-89 yrs) performed a battery of 33 daily activities in a standardized laboratory setting while a tri-axial accelerometer collected data from the right wrist. A portable metabolic unit was worn to measure metabolic intensity. We built deep lea…
ThinGenious PC(ThinGenious个人计算机公司);University of West Attica(西阿提卡大学);University of Bologna(博洛尼亚大学)
Nowadays, Hearth Rate (HR) monitoring is a key feature of almost all wrist-worn devices exploiting photoplethysmography (PPG) sensors. However, arm movements affect the performance of PPG-based HR tracking. This issue is usually addressed by fusing the PPG signal with data produced by inertial measurement units. Thus, deep learning algorithms have been proposed, but they are considered too complex to deploy on wearable devices and lack the explainability of results. In this work, we present a new deep learning model, PULSE, which exploits temporal convolutions and multi-head cross-attention to…
The current dominated wearable body motion sensor is IMU. This work presented an alternative wearable motion-sensing approach: human body capacitance (HBC, also commonly defined as body-area electric field). While being less robust in tracking the posture and trajectory, HBC has two properties that make it an attractive. First, the deployment of the sensing node on the being tracked body part is not a requirement for HBC sensing approach. Second, HBC is sensitive to the body's interaction with its surroundings, including both touching and being in the immediate proximity of people and objects.…
We address the well-known wearable activity recognition problem of having to work with sensors that are non-optimal in terms of information they provide but have to be used due to wearability/usability concerns (e.g. the need to work with wrist-worn IMUs because they are embedded in most smart watches). To mitigate this problem we propose a method that facilitates the use of information from sensors that are only present during the training process and are unavailable during the later use of the system. The method transfers information from the source sensors to the latent representation of th…
University of Bologna(博洛尼亚大学);Politecnico di Torino(都灵理工大学);ETH Zurich(苏黎世联邦理工学院)
Photoplethysmography (PPG) sensors allow for non-invasive and comfortable heart-rate (HR) monitoring, suitable for compact wrist-worn devices. Unfortunately, Motion Artifacts (MAs) severely impact the monitoring accuracy, causing high variability in the skin-to-sensor interface. Several data fusion techniques have been introduced to cope with this problem, based on combining PPG signals with inertial sensor data. Until know, both commercial and reasearch solutions are computationally efficient but not very robust, or strongly dependent on hand-tuned parameters, which leads to poor generalizati…
Sleep is restoration process of the body. The efficiency of this restoration process is directly correlated to the amount of time spent at each sleep phase. Hence, automatic tracking of sleep via wearable devices has attracted both the researchers and industry. Current state-of-the-art sleep tracking solutions are memory and processing greedy and they require cloud or mobile phone connectivity. We propose a memory efficient sleep tracking architecture which can work in the embedded environment without needing any cloud or mobile phone connection. In this study, a novel architecture is proposed…
Sleep is among the most important factors affecting one's daily performance, well-being, and life quality. Nevertheless, it became possible to measure it in daily life in an unobtrusive manner with wearable devices. Rather than camera recordings and extraction of the state from the images, wrist-worn devices can measure directly via accelerometer, heart rate, and heart rate variability sensors. Some measured features can be as follows: time to bed, time out of bed, bedtime duration, minutes to fall asleep, and minutes after wake-up. There are several studies in the literature regarding sleep q…
University of Bologna(博洛尼亚大学);Politecnico di Torino(都灵理工大学)
A wrist-worn PPG sensor coupled with a lightweight algorithm can run on a MCU to enable non-invasive and comfortable monitoring, but ensuring robust PPG-based heart-rate monitoring in the presence of motion artifacts is still an open challenge. Recent state-of-the-art algorithms combine PPG and inertial signals to mitigate the effect of motion artifacts. However, these approaches suffer from limited generality. Moreover, their deployment on MCU-based edge nodes has not been investigated. In this work, we tackle both the aforementioned problems by proposing the use of hardware-friendly Temporal…
University of Bologna(博洛尼亚大学);University of Modena and Reggio Emilia(摩德纳-雷焦艾米利亚大学);ETH Zurich(苏黎世联邦理工学院);Politecnico di Torino(都灵理工大学)
Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs) caused by movements of the subject's arm affect the performance of PPG-based HR tracking. This is typically addressed coupling the PPG signal with acceleration measurements from an inertial sensor. Unfortunately, most standard approaches of this kind rely on hand-tuned parameters, which impair their generalization capabilities and their applicability to real data in the field. In contrast, methods based on deep learning, despite their be…