The design of liquid-crystal diffractive phase plate coronagraphs for ground-based and space-based high-contrast imaging systems is limited by the trade-off between spectral bandwidth and polarization leakage. We demonstrate that by combining phase patterns with a polarization grating (PG) pattern directly followed by one or several separate PGs, we can suppress the polarization leakage terms by additional orders of magnitude by diffracting them out of the beam. \textcolor{black}{Using two PGs composed of a single-layer liquid crystal structure in the lab, we demonstrate a leakage suppression of more than an order of magnitude over a bandwidth of 133 nm centered around 532 nm. At this center wavelength we measure a leakage suppression of three orders of magnitude.} Furthermore, simulations indicate that a combination of two multi-layered liquid-crystal PGs can suppress leakage to $<10^{-5}$ for 1-2.5 $μ$m and $<10^{-10}$ for 650-800 nm. We introduce multi-grating solutions with three or more gratings that can be designed to have no separation of the two circular polarization states, and offer even deeper suppression of polarization leakage. We present simulations of a triple-grating solution that has $<10^{-10}$ leakage on the first Airy ring from 450 nm to 800 nm. We apply the double-grating concept to the Vector-Vortex coronagraph of charge 4, and demonstrate in the lab that polarization leakage no longer limits the on-axis suppression for ground-based contrast levels. Lastly, we report on the successful installation and first-light results of a double-grating vector Apodizing Phase Plate pupil-plane coronagraph installed at the Large Binocular Telescope. We discuss the implications of these new coronagraph architectures for high-contrast imaging systems on the ground and in space.
Coronagraphy is an efficient technique for identifying and characterizing extra-solar planets orbiting in the habitable zone of their parent star. An important family of coronagraphs is based on amplitude or phase filters placed at an intermediate image plane of the optical system, spreading starlight outside of the so-called Lyot stop located at the exit pupil plane of the instrument. This article explores the potential of circular amplitude and phase gratings employed as image plane coronagraph filters. It presents a theoretical analysis of the simplest case of an amplitude circular grating …
Context. The Annular Groove Phase Mask (AGPM) is one possible implementation of the vector vortex coronagraph, where the helical phase ramp is produced by a concentric subwavelength grating. For several years, we have been manufacturing AGPMs by etching gratings into synthetic diamond substrates using inductively coupled plasma etching. Aims. We aim to design, fabricate, optimize, and evaluate new L-band AGPMs that reach the highest possible coronagraphic performance, for applications in current and forthcoming infrared high-contrast imagers. Methods. Rigorous coupled wave analysis (RCWA) is u…
Phase-mask coronagraphs are known to provide high contrast imaging capabilities while preserving a small inner working angle, which allows searching for exoplanets or circumstellar disks with smaller telescopes or at longer wavelengths. The AGPM (Annular Groove Phase Mask, Mawet et al. 2005) is an optical vectorial vortex coronagraph (or vector vortex) induced by a rotationally symmetric subwavelength grating (i.e. with a period smaller than λ/n, λ being the observed wavelength and n the refractive index of the grating substrate). In this paper, we present our first mid- infrared AGPM prototyp…
One possible solution to achieve high contrast direct imaging at a small inner working angle (IWA) is to use a vector vortex coronagraph (VVC), which provides a continuous helical phase ramp in the focal plane of the telescope with a phase singularity in its center. Such an optical vortex is characterized by its topological charge, i.e., the number of times the phase accumulates 2π radians along a closed path surrounding the singularity. Over the past few years, we have been developing a charge-2 VVC induced by rotationally symmetric subwavelength gratings (SGVC2), also known as the Annular Gr…
Coronagraphy is a powerful technique to achieve high contrast imaging and hence to image faint companions around bright targets. Various concepts have been used in the visible and near-infrared regimes, while coronagraphic applications in the mid-infrared remain nowadays largely unexplored. Vector vortex phase masks based on concentric subwavelength gratings show great promise for such applications. We aim at producing and validating the first high-performance broadband focal plane phase mask coronagraphs for applications in the mid-infrared regime, and in particular the L band with a fraction…
Broadband coronagraphy with deep nulling and small inner working angle has the potential of delivering images and spectra of exoplanets and other faint objects. In recent years, many coronagraphic schemes have been proposed, the most promising being the optical vortex phase mask coronagraphs. In this paper, a new scheme of broadband optical scalar vortex coronagraph is proposed and characterized experimentally in the laboratory. Our setup employs a pair of computer generated phase gratings (one of them containing a singularity) to control the chromatic dispersion of phase plates and achieves a…
We present designs for fully achromatic vector Apodizing Phase Plate (vAPP) coronagraphs, that implement low polarization leakage solutions and achromatic beam-splitting, enabling observations in broadband filters. The vAPP is a pupil plane optic, inducing the phase through the inherently achromatic geometric phase. We discuss various implementations of the broadband vAPP and set requirements on all the components of the broadband vAPP coronagraph to ensure that the leakage terms do not limit a raw contrast of 1E-5. Furthermore, we discuss superachromatic QWPs based of liquid crystals or quart…
The direct-write technology for liquid-crystal patterns allows for manufacturing of extreme geometric phase patterned coronagraphs that are inherently broadband, e.g. the vector Apodizing Phase Plate (vAPP). We present on-sky data of a double-grating vAPP operating from 2-5 $μm$ with a 360-degree dark hole and a decreased leakage term of $\sim 10^{-4}$. We report a new liquid-crystal design used in a grating-vAPP for SCExAO that operates from 1-2.5$μm$. Furthermore, we present wavelength-selective vAPPs that work at specific wavelength ranges and transmit light unapodized at other wavelengths.…
In recent years, phase mask coronagraphy has become increasingly efficient in imaging the close environment of stars, enabling the search for exoplanets and circumstellar disks. Coronagraphs are ideally suited instruments, characterized by high dynamic range imaging capabilities, while preserving a small inner working angle. The AGPM (Annular Groove Phase Mask, Mawet et al. 2005) consists of a vector vortex induced by a rotationally symmetric subwavelength grating. This technique constitutes an almost unique solution to the achromatization at longer wavelengths (mid-infrared). For this reason,…
In recent years, new coronagraphic schemes have been proposed, the most promising being the optical vortex phase mask coronagraphs. In our work, a new scheme of broadband optical scalar vortex coronagraph is proposed and characterized experimentally in the laboratory. Our setup employs a pair of computer generated phase gratings (one of them containing a singularity) to control the chromatic dispersion of phase plates and achieves a constant peak-to-peak attenuation below 1:1000 over a bandwidth of 120 nm centered at 700 nm. An inner working angle of $λ$/D is demonstrated along with a raw cont…
Coronagraphy is a very efficient technique for identifying and characterizing extra-solar planets orbiting in the habitable zone of their parent star, especially when used in a space environment. An important family of coronagraphs is based on phase plates located at an intermediate image plane of the optical system, that spread the starlight outside the "Lyot" exit pupil plane of the instrument. In this communication we present a set of candidate phase functions generating a central null at the Lyot plane, and study how it propagates to the image plane of the coronagraph. These functions incl…
For several years, we have been developing vortex phase masks based on sub-wavelength gratings, known as Annular Groove Phase Masks. Etched onto diamond substrates, these AGPMs are currently designed to be used in the thermal infrared (ranging from 3 to 13 μm). Our AGPMs were first installed on VLT/NACO and VLT/VISIR in 2012, followed by LBT/LMIRCam in 2013 and Keck/NIRC2 in 2015. In this paper, we review the development, commissioning, on-sky performance, and early scientific results of these new coronagraphic modes and report on the lessons learned. We conclude with perspectives for future d…
High performance coronagraphic imaging of faint structures around bright stars at small angular separations requires fine control of tip, tilt and other low order aberrations. When such errors occur upstream of a coronagraph, they results in starlight leakage which reduces the dynamic range of the instrument. This issue has been previously addressed for occulting coronagraphs by sensing the starlight before or at the coronagraphic focal plane. One such solution, the coronagraphic low order wave-front sensor (CLOWFS) uses a partially reflective focal plane mask to measure pointing errors for Ly…
The ability to characterize exoplanets by spectroscopy of their atmospheres requires direct imaging techniques to isolate planet signal from the bright stellar glare. One of the limitations with the direct detection of exoplanets, either with ground- or space-based coronagraphs, is pointing errors and other low-order wavefront aberrations. The coronagraphic detection sensitivity at the diffraction limit therefore depends on how well low-order aberrations upstream of the focal plane mask are corrected. To prevent starlight leakage at the inner working angle of a phase mask coronagraph, we have …
We report on the performance of a vector apodizing phase plate coronagraph that operates over a wavelength range of $2-5 μ$m and is installed in MagAO/Clio2 at the 6.5 m Magellan Clay telescope at Las Campanas Observatory, Chile. The coronagraph manipulates the phase in the pupil to produce three beams yielding two coronagraphic point-spread functions (PSFs) and one faint leakage PSF. The phase pattern is imposed through the inherently achromatic geometric phase, enabled by liquid crystal technology and polarization techniques. The coronagraphic optic is manufactured using a direct-write techn…
Vortex coronagraphs are an attractive solution for imaging exoplanets with future space telescopes due to their relatively high throughput, large spectral bandwidth, and low sensitivity to low-order aberrations compared to other coronagraphs with similar inner working angles. Most of the vortex coronagraph mask development for space applications has focused on generating a polychromatic, vectorial, optical vortex using multiple layers of liquid crystal polymers. While this approach has been the most successful thus far, current fabrication processes achieve retardance errors of 0.1-1.0$^\circ$…