A combined ferrite parametric amplifier and millimeter-wave homodyne interferometer are proposed as an ambient temperature Bell Test. It is shown that the non-linear magnetic susceptibility of the yttrium iron garnet (YIG) ferrite, on account of its narrow line-width Larmor precessional resonance, make it an ideal material for the creation of entangled photons. These can be measured using a homodyne interferometer, as the much larger number of thermally generated photons associated with ambient temperature emission can be screened out. The proposed architecture may enable YIG quantum technology-based sensors to be developed, mimicking in the millimeter-wave band the large number of quantum optical experiments in the near-infrared and visible regions which had been made possible by use of the nonlinear beta barium borate ferroelectric, an analogue of YIG. It is illustrated here how the YIG parametric amplifier can reproduce quantum optical Type I and Type II wave interactions, which can be used to create entangled photons in the millimeter-wave band. It is estimated that when half a cubic centimeter of YIG crystal is placed in a magnetic field of a few Tesla and pumped with 5 Watts of millimeter-wave radiation, approximately 0.5x10^12 entangled millimeter-wave photon pairs per second are generated by the spin-wave interaction. This means an integration time of only a few tens of seconds is needed for a successful Bell Test. A successful demonstration of this will lead to novel architectures of entanglement-based quantum technology room temperature sensors, re-envisioning YIG as a modern quantum material.
The practical homodyne detector model of continuous-variable quantum key distribution models the inherent imperfections of the practical homodyne detector, namely the limited detection efficiency and the electronic noise, into trusted loss. However, the conventional practical homodyne detector model is valid only when both the imperfections of the practical homodyne detector are calibrated. In this paper, we show a modified practical homodyne detector model that can model the imperfections separately. The phase-sensitive amplifier is further applied to compensate the imperfections of the pract…
Traditional method for measuring continuous-variable quantum entanglement relies on balanced homodyne detections, which are sensitive to vacuum quantum noise coupled in through losses resulted from many factors such as detector's quantum efficiency and mode mismatching between detected field and local oscillator. In this paper, we propose and analyze a new measurement method, which is realized by assisting the balanced homodyne detections with a high gain phase sensitive parametric amplifier. The employment of the high gain parametric amplifier helps to tackle the vacuum quantum noise originat…
We design and demonstrate a resonant-type differential photodetector for low-noise quantum homodyne measurement at 500MHz optical sideband with 17MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer circuit, a low-noise voltage amplifier is realized and applied to our detector. 12dB of signal-to-noise ratio of the shot noise to the electric noise is obtained with 5mW of continuous-wave local oscillator. We analyze the frequency response and the noise characteristics of a resonant photodetector, and the theoretical model agrees with the shot noise measuremen…
We present a continuous-variable experimental analysis of a two-photon Fock state of free-propagating light. This state is obtained from a pulsed non-degenerate parametric amplifier, which produces two intensity-correlated twin beams. Counting two photons in one beam projects the other beam in the desired two-photon Fock state, which is analyzed by using a pulsed homodyne detection. The Wigner function of the measured state is clearly negative. We developed a detailed analytic model which allows a fast and efficient analysis of the experimental results.
We propose a new scheme for realizing nonlocal nondegenerate optical parametric amplifier by means of genuine four-mode entanglement. The nondegenerate optical parametric amplifier is regarded as a unitary transformation from two input fields to two outputs. Two inputs and two outputs are located at the remote stations respectively. Employing off-line four-mode entanglement, homodyne detection, classical communication and local displacement, the nonlocal nondegenerate optical parametric amplifier can be achieved. This scheme can be implemented with a setup that is experimentally accessible at …
A simple scheme for conditional generation of nonclassical light with sub-Poissonian photon-number statistics is proposed. The method utilizes entanglement of signal and idler modes in two-mode squeezed vacuum state generated in optical parametric amplifier. A quadrature component of the idler mode is measured in balanced homodyne detector and only those experimental runs where the absolute value of the measured quadrature is higher than certain threshold are accepted. If the threshold is large enough then the conditional output state of signal mode exhibits reduction of photon-number fluctuat…
A self-homodyne detection scheme is proposed to perform two-mode tomography on a twin-beam state at the output of a nondegenerate optical parametric amplifier. This scheme has been devised to improve the matching between the local oscillator and the signal modes, which is the main limitation to the overall quantum efficiency in conventional homodyning. The feasibility of the measurement is analyzed on the basis of Monte-Carlo simulations, studying the effect of non-unit quantum efficiency on detection of the correlation and the total photon-number oscillations of the twin-beam state.
We experimentally demonstrated that the quantum correlations of amplitude and phase quadratures between signal and idler beams produced from a non-degenerate optical parametric amplifier (NOPA) can be significantly improved by using a mode cleaner in the pump field and reducing the phase fluctuations in phase locking systems. Based on the two technical improvements the quantum entanglement measured with a two-mode homodyne detector is enhanced from ~ 4 dB to ~ 6 dB below the quantum noise limit using the same NOPA and nonlinear crystal.
Quantum mechanics imposes that any amplifier that works independently on the phase of the input signal has to introduce some excess noise. The impossibility of such a noiseless amplifier is rooted into unitarity and linearity of quantum evolution. A possible way to circumvent this limitation is to interrupt such evolution via a measurement, providing a random outcome able to herald a successful - and noiseless - amplification event. Here we show a successful realisation of such an approach; we perform a full characterization of an amplified coherent state using quantum homodyne tomography, and…
We present a conditional experiment involving a parametric amplifier and an avalanche photodetector to generate highly nonclassical states of the radiation field. The nonclassicality is robust against amplifier gain, detector efficiency and dark counts. At the output all the generalized Wigner functions have negative values, and this is exploited in order to reveal the nonclassicality through quantum homodyne tomography.
We present a homodyne detection scheme to verify Bell's inequality on correlated optical beams at the output of a nondegenerate parametric amplifier. Our approach is based on tomographic measurement of the joint detection probabilities, which allows high quantum efficiency at detectors. A self-homodyne scheme is suggested to simplify the experimental set-up.
We perform a detailed analysis of how an amplified interferometer can be used to enhance the quality of a dispersive qubit measurement, such as one performed on a superconducting transmon qubit, using homodyne detection on an amplified microwave signal. Our modeling makes a realistic assessment of what is possible in current circuit-QED experiments; in particular, we take into account the frequency-dependence of the qubit-induced phase shift for short microwaves pulses. We compare the possible signal-to-noise ratios obtainable with (single-mode) SU(1,1) interferometers with the current coheren…
The linear time-dependent constants of motion of the parametric amplifier are obtained and used to determine in the tomographic-probability representation the evolution of a general two-mode Gaussian state. By means of the discretization of the continuous variable density matrix, the von Neumann and linear entropies are calculated to measure the entanglement properties between the modes of the amplifier. The obtained results for the nonlocal correlations are compared with those associated to a linear map of discretized symplectic Gaussian-state tomogram onto a qubit tomogram. This qubit portra…
By invoking the quantum theory of optical coherence, we theoretically show that the quantum noise in conventional optical heterodyne devices, which were previously identified as usual phase-insensitive amplifiers with additional quantum noise, is similar to that in optical homodyne devices, as verified by experimental data. Albeit more study is demanded to understand this result, it is certain that neither the uncertainty principle nor Caves's theorem for quantum noise of linear amplifiers sets a limit to the quantum noise of heterodyne devices.
The sensitivity properties of an SU(1,1) interferometer made of two cascaded parametric amplifiers, as well as of an ordinary SU(2) interferometer preceded by a squeezer and followed by an anti-squeezer, are theoretically investigated. Several possible experimental configurations are considered, such as the absence or presence of a seed beam, direct or homodyne detection scheme. In all cases we formulate the optimal conditions to achieve phase super-sensitivity, meaning a sensitivity overcoming the shot-noise limit. We show that for a given gain of the first parametric amplifier, unbalancing t…
We present a comprehensive theory and an easy to follow method for the design and construction of a wideband homodyne detector for time-domain quantum measurements. We show how one can evaluate the performance of a detector in a specific time-domain experiment based on electronic spectral characteristic of that detector. We then present and characterize a high-performance detector constructed using inexpensive, commercially available components such as low-noise high-speed operational amplifiers and high-bandwidth photodiodes. Our detector shows linear behavior up to a level of over 13 dB clea…
Superconducting qubits are a leading platform for scalable quantum computing and quantum error correction. One feature of this platform is the ability to perform projective measurements orders of magnitude more quickly than qubit decoherence times. Such measurements are enabled by the use of quantum-limited parametric amplifiers in conjunction with ferrite circulators - magnetic devices which provide isolation from noise and decoherence due to amplifier backaction. Because these non-reciprocal elements have limited performance and are not easily integrated on-chip, it has been a longstanding g…
Traditionally, quantum amplification limit refers to the property of inevitable noise addition on canonical variables when the field amplitude of an unknown state is linearly transformed through a quantum channel. Recent theoretical studies have determined amplification limits for cases of probabilistic quantum channels or general quantum operations by specifying a set of input states or a state ensemble. However, it remains open how much excess noise on canonical variables is unavoidable and whether there exists a fundamental trade-off relation between the canonical pair in a general amplific…
We describe a novel tool for the quantum characterization of optical devices. The experimental setup involves a stable reference state that undergoes an unknown quantum transformation and is then revealed by balanced homodyne detection. Through tomographic analysis on the homodyne data we are able to characterize the signal and to estimate parameters of the interaction, such as the loss of an optical component, or the gain of an amplifier. We present experimental results for coherent signals, with application to the estimation of losses introduced by simple optical components, and show how the…
The measurement of a quantum system is often performed by encoding its state in a single observable of a light field. The measurement efficiency of this observable can be reduced by loss or excess noise on the way to the detector. Even a \textit{quantum-limited} detector that simultaneously measures a second non-commuting observable would double the output noise, therefore limiting the efficiency to $50\%$. At microwave frequencies, an ideal measurement efficiency can be achieved by noiselessly amplifying the information-carrying quadrature of the light field, but this has remained an experime…
Josephson parametric amplifiers (JPA) are promising devices for applications in circuit quantum electrodynamics (QED) and for studies on propagating quantum microwaves because of their good noise performance. In this work, we present a systematic characterization of a flux-driven JPA at millikelvin temperatures. In particular, we study in detail its squeezing properties by two different detection techniques. With the homodyne setup, we observe squeezing of vacuum fluctuations by superposing signal and idler bands. For a quantitative analysis we apply dual-path cross-correlation techniques to r…
Quantum tomography is the standard method of reconstructing the Wigner function of quantum states of light by means of balanced homodyne detection. The reconstruction quality strongly depends on the photodetectors quantum efficiency and other losses in the measurement setup. In this article we analyse in detail a protocol of enhanced quantum tomography, proposed by Leonhardt and Paul in 1994, which allows one to reduce the degrading effect of detection losses. It is based on phase sensitive parametric amplification, with the phase of the amplified quadrature being scanned synchronously with th…
We produce a 600-ns pulse of 1.86-dB squeezed vacuum at 795 nm in an optical parametric amplifier and store it in a rubidium vapor cell for 1 us using electromagnetically induced transparency. The recovered pulse, analyzed using time-domain homodyne tomography, exhibits up to 0.21+-0.04 dB of squeezing. We identify the factors leading to the degradation of squeezing and investigate the phase evolution of the atomic coherence during the storage interval.
We study the phase sensitivity in the conventional $SU(2)$ and nonconventional $SU(1,1)$ interferometers with the coherent and squeezed vacuum input state via the quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections, are nearly optimal. We also find that unlike the coherent state and squeezed vacuum state, the effects of the imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic …
Continuous-variable optical quantum information processing (CVOQIP), where quantum information is encoded in a traveling wave of light called a flying qubit, is a candidate for a practical quantum computer with high clock frequencies. Homodyne detectors for quadrature-phase amplitude measurements have been the major factor limiting the clock frequency. Here, we developed a real-time amplitude measurement method using a modular optical parametric amplifier (OPA) and a broadband balanced photodiode that is commercially used for coherent wavelength-division multiplexing telecommunication of the f…
Entangled multi-spatial-mode fields have interesting applications in quantum information, such as parallel quantum information protocols, quantum computing, and quantum imaging. We study the use of a nondegenerate four-wave mixing process in rubidium vapor at 795 nm to demonstrate generation of quantum-entangled images. Owing to the lack of an optical resonator cavity, the four-wave mixing scheme generates inherently multi-spatial-mode output fields. We have verified the presence of entanglement between the multi-mode beams by analyzing the amplitude difference and the phase sum noise using a …
Nonlinear interferometers that replace beamsplitters in Mach-Zehnder interferometers with nonlinear amplifiers for quantum-enhanced phase measurements have drawn increasing interest in recent years, but practical quantum sensors based on nonlinear interferometry remain an outstanding challenge. Here, we demonstrate the first practical application of nonlinear interferometry by measuring the displacement of an atomic force microscope microcantilever with quantum noise reduction of up to 3~dB below the standard quantum limit, corresponding to a quantum-enhanced measurement of beam displacement o…
We theoretically study the angular displacements estimation based on a modified Mach-Zehnder interferometer (MZI), in which two optical parametric amplifiers (PAs) are introduced into two arms of the standard MZI, respectively. The employment of PAs can both squeeze the shot noise and amplify the photon number inside the interferometer. When the unknown angular displacements are introduced to both arms, we derive the multiparameter quantum Cramér-Rao bound (QCRB) using the quantum Fisher information matrix approach, and the bound of angular displacements difference between the two arms is comp…
Floodlight quantum key distribution (FL-QKD) is a radically different QKD paradigm that can achieve Gbit/s secret-key rates over metropolitan area distances without multiplexing [Phys. Rev. A 94, 012322 (2016)]. It is a two-way protocol that transmits many photons per bit duration and employs a high-gain optical amplifier, neither of which can be utilized by existing QKD protocols to mitigate channel loss. FL-QKD uses an optical bandwidth that is substantially larger than the modulation rate and performs decoding with a unique broadband homodyne receiver. Essential to FL-QKD is Alice's injecti…