Intuitive control of prostheses relies on training algorithms to correlate biological recordings to motor intent. The quality of the training dataset is critical to run-time performance, but it is difficult to label hand kinematics accurately after the hand has been amputated. We quantified the accuracy and precision of labeling hand kinematics for two different approaches: 1) assuming a participant is perfectly mimicking predetermined motions of a prosthesis (mimicked training), and 2) assuming a participant is perfectly mirroring their contralateral hand during identical bilateral movements (mirrored training). We compared these approaches in non-amputee individuals, using an infrared camera to track eight different joint angles of the hands in real-time. Aggregate data revealed that mimicked training does not account for biomechanical coupling or temporal changes in hand posture. Mirrored training was significantly more accurate and precise at labeling hand kinematics. However, when training a modified Kalman filter to estimate motor intent, the mimicked and mirrored training approaches were not significantly different. The results suggest that the mirrored training approach creates a more faithful but more complex dataset. Advanced algorithms, more capable of learning the complex mirrored training dataset, may yield better run-time prosthetic control.
The dexterity of conventional myoelectric prostheses is limited in part by the small datasets used to train the control algorithms. Variations in surface electrode positioning make it difficult to collect consistent data and to estimate motor intent reliably over time. To address these challenges, we developed an inexpensive, easy-to-don sleeve that can record robust and repeatable surface electromyography from 32 embedded monopolar electrodes. Embedded grommets are used to consistently align the sleeve with natural skin markings (e.g., moles, freckles, scars). The sleeve can be manufactured i…
University of Utah(犹他大学);Department of Neurosurgery, University of Utah(犹他大学神经外科)
Bypass sockets allow researchers to perform tests of prosthetic systems from the prosthetic user's perspective. We designed a modular upper-limb bypass socket with 3D-printed components that can be easily modified for use with a variety of terminal devices. Our bypass socket preserves access to forearm musculature and the hand, which are necessary for surface electromyography and to provide substituted sensory feedback. Our bypass socket allows a sufficient range of motion to complete tasks in the frontal working area, as measured on non-amputee participants. We examined the performance of non…
Myoelectric prosthetic hands are intended to replace the function of the amputee's lost arm. Therefore, developing robotic prosthetics that can mimic not only the appearance and functionality of humans but also characteristics unique to human movements is paramount. Although the impedance model was proposed to realize biomimetic control, this model cannot replicate the characteristics of human movements effectively because the joint angle always converges to the equilibrium position during muscle relaxation. This paper proposes a novel biomimetic control method for myoelectric prosthetic hands…
Shangai Jiao Tong University(上海交通大学);The University of Electro-Communications(电气通信大学)
On the base of the developed master-slave prosthetic hand-arm robot system, which is controlled mainly based on signals obtained from bending sensors fixed on the data glove, the first idea deduced was to develop and add a multi-dimensional filter into the original control system to make the control signals cleaner and more stable at real time. By going further, a second new idea was also proposed to predict new control information based on the combination of a new algorithm and prediction control theory. In order to fulfill the first idea properly, the possible methods to process data in real…
Dexterous prosthetic hands have better grasp performance than traditional ones. However, patients still find it difficult to use these hands without a suitable control system. A new hybrid myoelectric control system, termed i-MYO, is presented and evaluated to solve this problem. The core component of the i-MYO is a novel grasp-type switching interface based on eye-tracking and augmented reality (AR), termed i-GSI. With the i-GSI, the user can easily switch a grasp type (six total) for a prosthetic hand by gazing at a GazeButton. The i-GSI is implemented in an AR helmet and is integrated, as a…
Multiarticulate bionic arms are now capable of mimicking the endogenous movements of the human hand. 3D-printing has reduced the cost of prosthetic hands themselves, but there is currently no low-cost alternative to dexterous electromyographic (EMG) control systems. To address this need, we developed an inexpensive (~$675) and portable EMG control system by integrating low-cost microcontrollers with an EMG acquisition device. We validated signal acquisition by comparing the signal-to-noise ratio (SNR) of our system with that of a high-end research-grade system. We also demonstrate the ability …
Hajim School of Engineering and Applied Sciences(哈吉米工程与应用科学学院);University of Rochester(罗切斯特大学)
The hand is one of the most complex and important parts of the human body. The dexterity provided by its multiple degrees of freedom enables us to perform many of the tasks of daily living which involve grasping and manipulating objects of interest. Contemporary prosthetic devices for people with transradial amputations or wrist disarticulation vary in complexity, from passive prosthetics to complex devices that are body or electrically driven. One of the important challenges in developing smart prosthetic hands is to create devices which are able to mimic all activities that a person might pe…
Johns Hopkins School of Medicine(约翰斯·霍普金斯大学医学院);Max Planck Institute for Intelligent Systems(马克斯·普朗克智能系统研究所);Johns Hopkins University(约翰斯·霍普金斯大学)
The lack of haptically aware upper-limb prostheses forces amputees to rely largely on visual cues to complete activities of daily living. In contrast, able-bodied individuals inherently rely on conscious haptic perception and automatic tactile reflexes to govern volitional actions in situations that do not allow for constant visual attention. We therefore propose a myoelectric prosthesis system that reflects these concepts to aid manipulation performance without direct vision. To implement this design, we built two fabric-based tactile sensors that measure contact location along the palmar and…
National University of Science and Technology (NUST)(巴基斯坦国立科技大学)
The issues of research required in the field of bio medical engineering and externally-powered prostheses are attracting attention of regulatory bodies and the common people in various parts of the globe. Today, 90 percent of prostheses used are conventional body powered cable-controlled ones which are very uncomfortable to the amputees as fairly large amount of forces and excursions have to be generated by the amputee. Additionally, its amount of rotation is limited. Alternatively, prosthetic limbs driven using electrical motors might deliver added functionality and improved control, accompan…
Prosthetic Hand Manipulation System Based on EMG and Eye Tracking Powered by the Neuromorphic Processor AltAi
Skolkovo Institute of Science and Technology(斯克尔科沃科学与技术研究所);MSU Institute for Artificial Intelligence(莫斯科大学人工智能研究所);Lomonosov Moscow State University(罗蒙诺索夫莫斯科国立大学)
George Mason University(乔治梅森大学);Center for Adaptive Systems of Brain-Body Interactions(脑-体交互自适应系统中心);Infinite Biomedical Technologies(无限生物医学技术公司);MedStar National Rehabilitation Hospital(MedStar国家康复医院)
Technological advances in multi-articulated prosthetic hands have outpaced the methods available to amputees to intuitively control these devices. Amputees often cite difficulty of use as a key contributing factor for abandoning their prosthesis, creating a pressing need for improved control technology. A major challenge of traditional myoelectric control strategies using surface electromyography electrodes has been the difficulty in achieving intuitive and robust proportional control of multiple degrees of freedom. In this paper, we describe a new control method, proprioceptive sonomyographic…
The control of multi-fingered dexterous prosthetics hand remains challenging due to the lack of an intuitive and efficient Grasp-type Switching Interface (GSI). We propose a new GSI (i-GSI) t hat integrates the manifold power of eye-tracking and augmentced reality technologies to solve this problem. It runs entirely in a HoloLens2 helmet, where users can glance at icons on the holographic interface to switch between six daily grasp types quickly. Compared to traditional GSIs (FSM-based, PR-based, and mobile APP-based), i-GSI achieved the best results in the experiment with eight healthy subjec…