arXiv 2001.03397q-bio.NCeess.SP
收藏

基于参考通道独立分量分析的脑磁图信号去噪

External noise removed from magnetoencephalographic signal using Independent Component Analyses of reference channels

Jeff Hanna, Cora Kim, Nadia Müller-Voggel

摘要:

背景资料:除了数据通道之外,许多脑磁图仪(MEG)还包含一组位于相对远离头部的位置的参考通道,其提供关于并非源自大脑的磁场的信息。该信息用于通过几何或最小均方(LMS)方法减去非神经源的源。LMS方法特别倾向于偏向于更恒定的噪声源,并且通常无法去除间歇性噪声。新方法:为了更好地识别和消除外部磁噪声,我们建议直接在MEG参考通道上执行ICA。在大多数情况下,这会产生几个分量,这些分量是具有不同时空模式的外部噪声源的清晰摘要。我们提出了两种算法,用于识别和消除这种噪声成分的数据,在许多情况下,可以显着提高数据质量。结果:我们使用包含大脑源和外部噪声源的前向模型进行了模拟。首先,应用传统的基于LMS的方法。虽然这消除了大量的噪音,但仍然保留了很大一部分。在许多情况下,这部分可以使用所提出的技术去除,几乎没有误报。与现有方法的比较:所提出的方法去除了现有基于LMS的方法往往不敏感的大量噪声。结论:该方法补充和扩展了传统的基于参考的噪声校正,具有很小的额外计算成本和低的误报率。任何带参考通道的脑磁图系统都可以从中受益,特别是在有间歇性噪声源的实验室中。

英文摘要:

Background: Many magnetoencephalographs (MEG) contain, in addition to data channels, a set of reference channels positioned relatively far from the head that provide information on magnetic fields not originating from the brain. This information is used to subtract sources of non-neural origin, with either geometrical or least mean squares (LMS) methods. LMS methods in particular tend to be biased toward more constant noise sources and are often unable to remove intermittent noise. New Method: To better identify and eliminate external magnetic noise, we propose performing ICA directly on the MEG reference channels. This in most cases produces several components which are clear summaries of external noise sources with distinct spatio-temporal patterns. We present two algorithms for identifying and removing such noise components from the data which can in many cases significantly improve data quality. Results: We performed simulations using forward models that contained both brain sources and external noise sources. First, traditional LMS-based methods were applied. While this removed a large amount of noise, a significant portion still remained. In many cases, this portion could be removed using the proposed technique, with little to no false positives. Comparison with existing method(s): The proposed method removes significant amounts of noise to which existing LMS-based methods tend to be insensitive. Conclusions: The proposed method complements and extends traditional reference based noise correction with little extra computational cost and low chances of false positives. Any MEG system with reference channels could profit from its use, particularly in labs with intermittent noise sources.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑