arXiv 1911.03136stat.AP
收藏

城市环境中二氧化氮测量的分级网络设计第2部分:基于网络的传感器校准

Hierarchical network design for nitrogen dioxide measurement in urban environments, part 2: network-based sensor calibration

Lena Weissert, Elaine Miles, Georgia Miskell, Kyle Alberti, Brandon Feenstra, Geoff S Henshaw, Vasileios Papapostolou, Hamesh Patel, Andrea Polidori, Jennifer A… 展开作者

Lena Weissert, Elaine Miles, Georgia Miskell, Kyle Alberti, Brandon Feenstra, Geoff S Henshaw, Vasileios Papapostolou, Hamesh Patel, Andrea Polidori, Jennifer A Salmond, David E Williams

摘要:

我们提出了一个管理和数据校正框架,用于部署在低成本和监管级仪器的分层网络内的二氧化氮(NO2)的低成本电化学传感器。该框架是建立在这样的想法,它是可能的,在一个适当配置的网络,以确定一个源的可靠的代理数据为每个传感器站点,具有一个类似的概率分布的测量值在一个合适的时间段。先前的工作成功地将这些想法应用于具有简单的线性2参数(斜率和偏移)响应的传感器系统。将这些想法应用于NO2电化学传感器提出了显着的额外困难,我们证明了解决方案。已知三个NO2传感器响应参数(偏移、臭氧(O3)响应斜率和NO2响应斜率)由于环境湿度和温度变化而显著变化。在这里,我们证明了这些响应参数可以通过最小化传感器估计和代理NO2分布在3天的窗口之间的库尔贝克-莱布勒散度来估计。然后,我们估计一个额外的偏移项使用共定位数据。这一偏移量取决于气候和空间相关性,因此可以在整个网络中进行预测。协同定位数据还可以估计传感器和监管级仪器之间的时间、空间和浓度相关的误差分布。我们展示了如何参数的变化可以用来指示传感器故障和代理假设的失败。我们将该程序应用于分布在内陆帝国和洛杉矶县地区的56个传感器网络,证明需要从密集的监测网络中获得可靠的数据,以补充现有的监管网络。

英文摘要:

We present a management and data correction framework for low-cost electrochemical sensors for nitrogen dioxide (NO2) deployed within a hierarchical network of low-cost and regulatory-grade instruments. The framework is founded on the idea that it is possible in a suitably configured network to identify a source of reliable proxy data for each sensor site that has a similar probability distribution of measurement values over a suitable time period. Previous work successfully applied these ideas to a sensor system with a simple linear 2-parameter (slope and offset) response. Applying these ideas to electrochemical sensors for NO2 presents significant additional difficulties for which we demonstrate solutions. The three NO2 sensor response parameters (offset, ozone (O3) response slope, and NO2 response slope) are known to vary significantly as a consequence of ambient humidity and temperature variations. Here we demonstrate that these response parameters can be estimated by minimising the Kullback-Leibler divergence between sensor-estimated and proxy NO2 distributions over a 3-day window. We then estimate an additional offset term by using co-location data. This offset term is dependent on climate and spatially correlated and can thus be projected across the network. Co-location data also estimates the time-, space- and concentration-dependent error distribution between sensors and regulatory-grade instruments. We show how the parameter variations can be used to indicate both sensor failure and failure of the proxy assumption. We apply the procedures to a network of 56 sensors distributed across the Inland Empire and Los Angeles County regions, demonstrating the need for reliable data from dense networks of monitors to supplement the existing regulatory networks.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑