毫米波和亚毫米波spectroscopy调频本振无离点观测新方法(FMLO)
A new off-point-less observing method for millimeter and submillimeter spectroscopy with a frequency-modulating local oscillator (FMLO)
摘要:
提出了一种利用调频本振外差接收机进行单碟毫米波和亚毫米波光谱观测的新方法。与传统的开关方法不同,传统的开关方法通过从开源的参考光谱中减去关源的参考光谱来提取天文信号,FMLO方法不需要获得任何关源光谱;相反,它从开源光谱本身估计它们。其原理是通过外差接收机的本地振荡器(LO)的快速扫描实现的具有射频调制(FM)的高转储速率(10 Hz)光谱学:离源)作为$1/f$型波动并且是谱相关的,它可以通过主成分分析从时间序列谱(时间流)中估计和减去。同时,天文信号保留在时间流中,因为它们被调制到更高的时频域。因此,FMLO方法实现了(1)非常高的观测效率,(2)减少了光谱基线摆动,以及(3)基于软件的边带分离。我们为野边山45米望远镜研制了一套调频振荡系统,并开发了相应的数据处理程序。银河系源的观测,我们证明了FMLO方法的观测效率显着提高相比,传统的开关方法。具体来说,我们发现,达到相同的噪声水平的时间减少了3.0倍,在单点观测和映射观测的一个因素的1.2。FMLO方法可应用于较暗($\sim$ mK)谱线和较大($\sim$ deg $^{2}$)映射的观测。与传统的切换方法相比,它将提供更有效和基线稳定的观测。
英文摘要:
We propose a new observing method for single-dish millimeter and submillimeter spectroscopy using a heterodyne receiver equipped with a frequency-modulating local oscillator (FMLO). Unlike conventional switching methods, which extract astronomical signals by subtracting the reference spectra of off-sources from those of on-sources, the FMLO method does not need to obtain any off-source spectra; rather, it estimates them from the on-source spectra themselves. The principle is a high dump-rate (10 Hz) spectroscopy with radio frequency modulation (FM) achieved by fast sweeping of a local oscillator (LO) of a heterodyne receiver: Because sky emission (i.e., off-source) fluctuates as $1/f$-type and is spectrally correlated, it can be estimated and subtracted from time-series spectra (a timestream) by principal component analysis. Meanwhile astronomical signals remain in the timestream since they are modulated to a higher time-frequency domain. The FMLO method therefore achieves (1) a remarkably high observation efficiency, (2) reduced spectral baseline wiggles, and (3) software-based sideband separation. We developed an FMLO system for the Nobeyama 45-m telescope and a data reduction procedure for it. Frequency modulation was realized by a tunable and programmable first local oscillator. With observations of Galactic sources, we demonstrate that the observation efficiency of the FMLO method is dramatically improved compared to conventional switching methods. Specifically, we find that the time to achieve the same noise level is reduced by a factor of 3.0 in single-pointed observations and by a factor of 1.2 in mapping observations. The FMLO method can be applied to observations of fainter ($\sim$mK) spectral lines and larger ($\sim$deg$^{2}$) mapping. It would offer much more efficient and baseline-stable observations compared to conventional switching methods.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。