arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1910.03555eess.SYcs.SY
收藏

中性点钳位逆变器调制技术的故障分析和可靠性评估--使用模型方法

Failure analysis and reliability evaluation of modulation techniques for neutral point clamped inverters-A usage model approach

Masoud Farhadi, Mehdi Abapour, Mehran Sabahi

摘要:

到目前为止,已经提出了许多中性点箝位(NPC)逆变器的调制技术。在本文中,第一次,一个一般的方法,适用于计算和比较的NPC逆变器的故障分析和可靠性与最常用的控制策略。此外,NPC逆变器的平均故障时间(MTTF)推导出不同的控制策略。它表明,在决定逆变器的可靠性的控制策略的关键特征是它们的开关之间的损失分配。建立了与本研究相关的元器件的失效率和结温计算公式,计算了不同控制策略下开关管的导通损耗和开关损耗。最后,确定最可靠的控制策略。所获得的实验结果及时证明了理论分析和概述的程序。

英文摘要:

Up to now, many modulation techniques have been proposed for neutral point clamped (NPC) inverters. In this paper, for the first time, a general methodology is applied to calculate and compare the failure analysis and reliability of NPC inverter with most commonly used control strategies. Also, the mean time to failure (MTTF) of NPC inverter is derived for different control strategies. It is demonstrated that the key feature of control strategies in determining the reliability of inverter is their loss distribution among the switches. The failure rate of components that is relevant to this study and junction temperature calculation is developed, then conduction losses and switching losses of switches for different control strategies are calculated. Finally, the most reliable control strategy is identified. Experimental results obtained have promptly justified the theoretical analysis and outlined procedure.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑