Reproducibility of an airway tapering measurement in CT with application to bronchiectasis

University College London(伦敦大学学院)

Kin Quan, Ryutaro Tanno, Rebecca J. Shipley, Jeremy S. Brown, Joseph Jacob, John R. Hurst, David J. Hawkes

摘要:

目的:本文提出了一种管道,以获取从隆突到CT上可见的单个气道的最远点的标量锥形测量。我们通过量化逐渐减少测量的可重复性,展示了使用逐渐减少测量对临床采集数据的适用性。方法:我们从气道中心线生成样条,以测量相邻间隔处的面积和弧长。锥形测量是对数空间中的面积与弧长之间的线性回归的梯度。通过分析单个时间点和纵向CT扫描上的不同辐射剂量、体素大小和重建内核以及通过评估气道分叉的影响来评估测量的再现性。结果如下:使用来自10次CT扫描的74个气道,我们显示了健康气道(n = 35)和支气管扩张影响的气道(n = 39)之间在逐渐减少方面的统计学差异,p = 3.4 $\times$ 10 $^{-4}$。两个群体的平均值之间的差异为0.011 mm $^{-1}$,两个群体的中位数之间的差异为0.006 mm $^{-1}$。在模拟的25 mAs扫描中,锥形测量保留了$\pm$ 0.005 mm $^{-1}$的95%置信区间,并在模拟CT上保留了$\pm$ 0.005 mm $^{-1}$的95%置信区间,最大值为原始体素尺寸的1.5倍。结论:我们已经建立了一个估计的锥形测量的精度,并估计模拟体素的大小和CT扫描剂量的精度的影响。我们建议使用所述的体模,在任何定量研究中使用的特定CT扫描仪、辐射剂量和重建算法上进行扫描仪校准。我们的代码可在https://github.com/quan14/AirwayTaperingInCT上获得

英文摘要:

Purpose: This paper proposes a pipeline to acquire a scalar tapering measurement from the carina to the most distal point of an individual airway visible on CT. We show the applicability of using tapering measurements on clinically acquired data by quantifying the reproducibility of the tapering measure. Methods: We generate a spline from the centreline of an airway to measure the area and arclength at contiguous intervals. The tapering measurement is the gradient of the linear regression between area in log space and arclength. The reproducibility of the measure was assessed by analysing different radiation doses, voxel sizes and reconstruction kernel on single timepoint and longitudinal CT scans and by evaluating the effct of airway bifurcations. Results: Using 74 airways from 10 CT scans, we show a statistical difference, p = 3.4 $\times$ 10$^{-4}$ in tapering between healthy airways (n = 35) and those affected by bronchiectasis (n = 39). The difference between the mean of the two populations was 0.011mm$^{-1}$ and the difference between the medians of the two populations was 0.006mm$^{-1}$. The tapering measurement retained a 95\% confidence interval of $\pm$0.005mm$^{-1}$ in a simulated 25 mAs scan and retained a 95% confidence of $\pm$0.005mm$^{-1}$ on simulated CTs up to 1.5 times the original voxel size. Conclusion: We have established an estimate of the precision of the tapering measurement and estimated the effect on precision of simulated voxel size and CT scan dose. We recommend that the scanner calibration be undertaken with the phantoms as described, on the specific CT scanner, radiation dose and reconstruction algorithm that is to be used in any quantitative studies. Our code is available at https://github.com/quan14/AirwayTaperingInCT

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑