arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1909.02082astro-ph.EP
收藏

用ROSINA双聚焦Mass Spectrometer测量罗塞塔任务期间67 P/Churyumov-Gerasimenko彗星核主要挥发性物质H2O、CO2、CO和O2的表面分布

The Surface Distributions of the Production of the Major Volatile Species, H2O, CO2, CO and O2, from the Nucleus of Comet 67P/Churyumov-Gerasimenko throughout the Rosetta Mission as Measured by the ROSINA Double Focusing Mass Spectrometer

Michael Combi, Yinsi Shou, Nicolas Fougere, Valeriy Tenishev, Kathrin Altwegg, Martin Rubin, Dominique Bockelée-Morvan, Fabrizio Capaccioni, Yu-Chi Cheng, Uwe F… 展开作者

Michael Combi, Yinsi Shou, Nicolas Fougere, Valeriy Tenishev, Kathrin Altwegg, Martin Rubin, Dominique Bockelée-Morvan, Fabrizio Capaccioni, Yu-Chi Cheng, Uwe Fink, Tamas Gombosi, Kenneth C. Hansen, Zhenguang Huang, David Marshall, Gabor Toth

摘要:

罗塞塔轨道飞行器离子和中性分析光谱仪(ROSINA)成套仪器在67 P/Churyumov-Gerasimenko彗星附近两年多的罗塞塔飞行任务作业期间一直在运行。它测量了整个彗星大气层(或称彗发)的气体密度和成分。在这里,我们提出了两年的测量值的四个主要挥发性物种的相对密度的彗星,水。CO2,CO和O2,由ROSINA子系统之一称为双聚焦质谱仪(DFMS)。绝对总气体密度由ROSINA的另一个子系统彗星压力传感器(COPS)提供。DFMS是一种非常高的质量分辨率和高灵敏度质谱仪,能够分辨原子质量单位的一小部分。我们已经分析了组合DFMS和COPS测量使用的反演方案的基础上,解决了潜在的表面活动的每个物种的分布作为彗星旋转,改变太阳光照,在短时间间隔内,作为彗星改变距离太阳和方向的自旋轴在很长的时间间隔。我们还使用来自反演方案的表面边界条件来模拟整个昏迷与我们的完全动力学直接模拟蒙特卡罗模型,并计算整个任务的四个主要物种的生产率。我们比较得出的生产率与修订后的遥感观测的可见光和红外热成像光谱仪(VIRTIS),以及从微波仪器的罗塞塔轨道器(MIRO)公布的意见。最后,我们使用的主要物种的表面生产的变化来计算总的质量损失的任务,并为不同的估计的灰尘/气体比,计算表面损失的变化超过核。

英文摘要:

The Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA) suite of instruments operated throughout the over two years of the Rosetta mission operations in the vicinity of comet 67P/Churyumov-Gerasimenko. It measured gas densities and composition throughout the comet's atmosphere, or coma. Here we present two-years' worth of measurements of the relative densities of the four major volatile species in the coma of the comet, H2O. CO2, CO and O2, by one of the ROSINA sub-systems called the Double Focusing Mass Spectrometer (DFMS). The absolute total gas densities were provided by the Comet Pressure Sensor (COPS), another ROSINA sub-system. DFMS is a very high mass resolution and high sensitivity mass spectrometer able to resolve at a tiny fraction of an atomic mass unit. We have analyzed the combined DFMS and COPS measurements using an inversion scheme based on spherical harmonics that solves for the distribution of potential surface activity of each species as the comet rotates, changing solar illumination, over short intervals and as the comet changes distance from the sun and orientation of its spin axis over long time intervals. We also use the surface boundary conditions derived from the inversion scheme to simulate the whole coma with our fully kinetic Direct Simulation Monte Carlo model and calculate the production rates of the four major species throughout the mission. We compare the derived production rates with revised remote sensing observations by the Visible and Infrared Thermal Imaging Spectrometer (VIRTIS) as well as with published observations from the Microwave Instrument for the Rosetta Orbiter (MIRO). Finally we use the variation of the surface production of the major species to calculate the total mass loss over the mission and, for different estimates of the dust/gas ratio, calculate the variation of surface loss over the nucleus.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑