The IceCube Neutrino Observatory will be upgraded in 2022/23. For this IceCube Upgrade and the planned enlarged detector IceCube-Gen2 new optical modules are under development. One of these optical modules, the Wavelength-shifting Optical Module (WOM), uses wavelength-shifting and light-guiding techniques to measure Cherenkov photons in the UV-range. To understand the potential improvements of this new module the absorption and scattering lengths of UV light in the South Pole ice need to be measured. The measurement is done utilizing an existing borehole (SPICEcore) of 1751 m depth. The SPICEcore hole was drilled for glaciological studies and filled with a transparent antifreeze liquid to remain accessible. To measure the UV optical properties a calibration device has been designed and lowered down into the hole. The device includes a UV light source and a UV-sensitive detector. UV photons scattered back are measured and from their time distribution the scattering and absorption length are calculated. We present the design of the probe and its performance during the 2018/19 measurement campaign.
IceCube is a cubic-kilometer scale neutrino telescope located at the geographic South Pole. The detector utilizes the extremely transparent Antarctic ice as a medium for detecting Cherenkov radiation from neutrino interactions. As a result of extensive studies of the optical properties of ice, the light propagation in IceCube is well understood. The ice properties are, however, still dominant sources of detector systematic uncertainties in many IceCube analyses. We have designed a camera system to measure the optical properties of the Antarctic ice surrounding the SPICEcore hole that is an ice…
The IceCube Neutrino Observatory, located at the geographic South Pole, is the world's largest neutrino telescope, instrumenting 1 km$^3$ of Antarctic ice with 5160 photosensors to detect Cherenkov light. For the IceCube Upgrade, to be deployed during the 2022-23 polar field season, and the enlarged detector IceCube-Gen2 several new optical sensor designs are under development. One of these optical sensors, the Wavelength-shifting Optical Module (WOM), uses wavelength-shifting and light-guiding techniques to measure Cherenkov photons in the UV range from 250 nm to 380 nm. In order to understan…
On October $10^{\rm th}$ 2018 started the commissioning of the first Large Size Telescope (LST) prototype at the Cherenkov Telescope Array (CTA) northern site at the Observatorio del Roque de los Muchachos, Canary Island of La Palma (Spain). For a precise event energy reconstruction, an LST camera requires a uniform and constant calibration over a large dynamic range, up to $10^{4}$ photo-electrons (p.e.), for each camera photomultiplier tube (PMT). This paper describes the performance of the LST-1 camera calibration system (named CaliBox) in the first commissioning period and provides prelimi…
The IceCube Neutrino Observatory will be upgraded with about 700 additional optical sensor modules and new calibration devices. Particularly, improved calibration will enhance IceCube's physics capabilities both at low and high neutrino energies. An important ingredient for a good angular resolution of the observatory is a precise calibration of the positions of optical sensors. We present the concept of newly developed acoustic sensors that are mounted inside the optical modules and additional acoustic emitter modules that are attached to the strings. With this system we aim for the calibrati…
A method is proposed and experimentally explored for in-situ calibration of complex transmission data for superconducting microwave resonators. This cryogenic calibration method accounts for the instrumental transmission response between the vector network analyzer reference plane and the device calibration plane. Once calibrated, the observed resonator response is analyzed in detail by two approaches. The first, a phenomenological model based on physically realizable rational functions, enables the extraction of multiple resonance frequencies and widths for coupled resonators without explicit…
Observational cosmology employing optical surveys often require precise flux calibration. In this context we present SNIFS Calibration Apparatus (SCALA), a flux calibration system developed for the SuperNova Integral Field Spectrograph (SNIFS), operating at the University of Hawaii 2.2 m telescope. SCALA consists of a hexagonal array of 18 small parabolic mirrors distributed over the face of, and feeding parallel light to, the telescope entrance pupil. The mirrors are illuminated by integrating spheres and a wavelength-tunable (from UV to IR) light source, generating light beams with opening a…
The atmospheric monitoring devices for the planned calibration system of the Cherenkov Telescope Array (CTA) are undergoing intensive development, prototyping and testing. The All-Sky Cameras, the Sun/Moon Photometers and the FRAM telescopes have been gradually deployed at the future CTA sites with the primary goal of site characterization, simultaneously allowing the assessment of their operational reliability in realistic environmental conditions. All three devices have shown the ability to work smoothly in both the extreme dryness and the large temperature variations of the southern site as…
X-ray spectrometer is one of the satellite payloads on Chang'E-2 satellite. The soft X-ray detector is one of the device on X-ray spectrometer which is designed to detect the major rock-forming elements within 0.5-10keV range on lunar surface. In this paper, energy linearity and energy resolution calibration is done using a weak Fe55 source, while temperature and time effect is considered not take big error. The total uncertainty is estimated to be within 5% after correction.
We describe a device (adapter) for off-axis guiding and photometric calibration of wide-angle spectrographs operating in the prime focus of the 6-m telescope of the Special Astrophysical Observatory of the Russian Academy of Sciences. To compensate coma in off-axis star images an achromatic lens corrector is used, which ensures maintaining image quality (FWHM) at a level of about 1'' within 15' from the optical axis. The device has two 54'-diameter movable guiding fields, which can move in 10' x 4'.5 rectangular areas. The device can perform automatic search for guiding stars, use them to cont…
Laser frequency combs are fast becoming critical to reaching the highest radial velocity precisions. One shortcoming is the highly variable brightness of the comb lines across the spectrum (up to 4-5 orders of magnitude). This can result in some lines saturating while others are at low signal and lost in the noise. Losing lines to either of these effects reduces the precision and hence effectiveness of the comb. In addition, the brightness of the comb lines can vary with time which could drive comb lines with initially reasonable SNR's into the two regimes described above. To mitigate these tw…
In this chapter we present a brief summary of methods, instruments and calibration techniques used in modern astronomical polarimetry in the optical wavelengths. We describe the properties of various polarization devices and detectors used for optical broadband, imaging and spectropolarimetry, and discuss their advantages and disadvantages. The necessity of a proper calibration of the raw polarization data is emphasized and methods of the determination and subtraction of instrumental polarization are considered. We also present a few examples of high-precision measurements of optical polarizat…
The Cherenkov Telescope Array is a project that aims to exploring the highest energy region of electromagnetic spectrum. Two arrays, one for each hemisphere, will cover the full sky in a range from few tens of GeV to hundreds of TeV improving the sensitivity and angular resolution of the present operating arrays. A prototype of the Large Size Telescope (LST) for the study of gamma ray astronomy above some tens of GeV will be installed at the Canary Island of La Palma in 2016. The LST camera, made by an array of photomultipliers (PMTs), requires an accurate and systematic calibration over a wid…
With the rise of neutrino astronomy using large-volume detector arrays, calibration improvements of optical media and photosensors have emerged as significant means to reduce detector systematics. To improve understanding of the detector volume and its instrumentation, we developed an absolutely-calibrated, self-monitoring, isotropic, nanosecond, high-intensity calibration light source called "Precision Optical Calibration Module" (POCAM). This now third iteration of the instrument was developed for an application in the IceCube Upgrade but, with a modular instrument communications and synchro…
Swept Charge Devices (SCD) are novel X-ray detectors optimized for improved spectral performance without any demand for active cooling. The Chandrayaan-1 X-ray Spectrometer (C1XS) experiment onboard the Chandrayaan-1 spacecraft used an array of SCDs to map the global surface elemental abundances on the Moon using the X-ray fluorescence (XRF) technique. The successful demonstration of SCDs in C1XS spurred an enhanced version of the spectrometer on Chandrayaan-2 using the next-generation SCD sensors. The objective of this paper is to demonstrate validation of a physical model developed to simula…
Prototyping the Next-Generation Spectrograph for Space Exploration: Digital Micromirror Device-based Multi-Object Spectrograph (DMD-MOS) Calibration and Performance Assessment
David A. Dunlap Department of Astronomy and Astrophysics, University of Toronto(多伦多大学天体物理学与天文学戴维·A·邓普勒系);Dunlap Institute for Astronomy and Astrophysics, University of Toronto(多伦多大学邓普勒天体物理与天文学研究所);Department of Physics, University of Toronto(多伦多大学物理系);Department of Electrical and Computer Engineering, University of Toronto(多伦多大学电气与计算机工程系);Steward Observatory & Department of Astronomy, University of Arizona(亚利桑那大学斯图尔德天文台及天文学系)