arXivDaily arXiv每日学术速递 周一至周五更新
​通知:联邦节假日调休:哥伦布日 / 原住民日(Columbus Day / Indigenous Peoples' Day),今日(13日)无更新。
arXiv 1908.09067q-bio.QMcs.AIcs.CVeess.IVq-bio.TO

Plexus Convolutional Neural Network (PlexusNet): A novel neural network architecture for histologic image analysis

Stanford School of Medicine(斯坦福医学院);Center for Artificial Intelligence in Medicine & Imaging(医学与人工智能中心);Department of Urology(泌尿外科);Institute for Pathology and Cytology, Schüttorf(许特霍夫病理与细胞研究所);Department of Radiology(放射科);Department of Biomedical Data Science(生物医学数据科学系)

Okyaz Eminaga, Mahmoud Abbas, Christian Kunder, Andreas M. Loening, Jeanne Shen, James D. Brooks, Curtis P. Langlotz, Daniel L. Rubin

英文摘要:

Different convolutional neural network (CNN) models have been tested for their application in histological image analyses. However, these models are prone to overfitting due to their large parameter capacity, requiring more data or valuable computational resources for model training. Given these limitations, we introduced a novel architecture (termed PlexusNet). We utilized 310 Hematoxylin and Eosin stained (H&E) annotated histological images of prostate cancer cases from TCGA-PRAD and Stanford University and 398 H&E whole slides images from the Camelyon 2016 challenge. PlexusNet-architecture -derived models were compared to models derived from several existing "state of the art" architectures. We measured discrimination accuracy, calibration, and clinical utility. An ablation study was conducted to study the effect of each component of PlexusNet on model performance. A well-fitted PlexusNet-based model delivered comparable classification performance (AUC: 0.963) in distinguishing prostate cancer from healthy tissues, although it was at least 23 times smaller, had a better model calibration and clinical utility than the comparison models. A separate smaller PlexusNet model accurately detected slides with breast cancer metastases (AUC: 0.978); it helped reduce the slide number to examine by 43.8% without consequences, although its parameter capacity was 200 times smaller than ResNet18. We found that the partitioning of the development set influences the model calibration for all models. However, with PlexusNet architecture, we could achieve comparable well-calibrated models trained on different partitions. In conclusion, PlexusNet represents a novel model architecture for histological image analysis that achieves classification performance comparable to other models while providing orders-of-magnitude parameter reduction.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑