Cable-driven robotic interface for lower limb neuromechanics identification

Imperial College of Science, Technology and Medicine(帝国理工学院);Queen Mary University of London(伦敦玛丽女王大学);University of Waterloo(滑铁卢大学);Toronto Rehabilitation Institute-University Health Network(多伦多康复研究所-大学健康网络);École Polytechnique Fédérale de Lausanne(洛桑联邦理工学院)

Hsien-Yung Huang, Ildar Farkhatdinov, Arash Arami, Mohamed Bouri, Etienne Burdet

英文摘要:

This paper presents a versatile cable-driven robotic interface to investigate the single-joint joint neuromechanics of the hip, knee and ankle. This endpoint-based interface offers highly dynamic interaction and accurate position control, as is typically required for neuromechanics identification. It can be used with the subject upright, corresponding to natural posture during walking or standing, and does not impose kinematic constraints on a joint, in contrast to existing interfaces. Mechanical evaluations demonstrated that the interface yields a rigidity above 500N/m with low viscosity. Tests with a rigid dummy leg and linear springs show that it can identify the mechanical impedance of a limb accurately. A smooth perturbation is developed and tested with a human subject, which can be used to estimate the hip neuromechanics.