基于荧光与FRET的汞(II)传感器
Fluorescence and FRET based mercury (II) sensor
AI总结:
本文提出一种基于NK与RhB之间FRET的汞离子传感器,利用NK对Hg2+的敏感性实现检测,检测限达9.13 ppb,并在真实湖水中验证有效。
摘要:
提出了一种基于N,N'-双十八烷基硫杂菁高氯酸盐(NK)与十八烷基罗丹明B氯化物(RhB)之间荧光共振能量转移(FRET)的汞(II)传感器。在这两种分子中,NK因含有硫原子而对Hg2+离子敏感。因此,Hg2+离子的存在会影响NK的荧光以及从NK到RhB的FRET。我们的结果表明,NK荧光强度和FRET效率随Hg2+离子浓度的增加而线性下降。经过适当优化,当前研究体系可用于检测水溶液中的Hg2+离子,检测限为9.13 ppb。该体系的优势在于与其他基于FRET的体系相比非常简单,并且可在水相环境中工作。该方法还使用真实湖水进行了测试,获得了令人满意的结果。
英文摘要:
A mercury (II) sensor has been proposed based on Fluorescence Resonance Energy Transfer (FRET) between N,N'-dioctadecyl thiacyanine perchlorate (NK) and Octadecyl rhodamine B chloride (RhB). Out of these two molecules NK is sensitive to Hg2+ ions due to presence of sulfur atom in it. Accordingly, presence of Hg2+ ions affects the NK fluorescence as well as FRET from NK to RhB. Our results showed that NK fluorescence intensity and FRET efficiency linearly decreases with increase in Hg2+ ion concentration. With proper optimization present system under investigations can be used to sense Hg2+ ions in aqueous solution with detection limit of 9.13 ppb. Advantage of this present system is that it is very simple compared to the other FRET based system and also it works under aqueous environment. This method has also been tested using real lake water and satisfactory results were obtained.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。