摘要:
在电力系统中,在异常扩大并导致严重故障(如停电或系统停电)之前,检测出异常是非常重要的。随着相量测量单元(PMU)的部署,收集了大量的同步相量测量,这使得整个系统的实时态势感知成为可能。基于随机矩阵理论,提出了一种数据驱动的电力系统异常检测方法。首先,时空数据集制定通过安排高维同步相量测量的时间顺序。基于RMT中的Ring定律对“信号+噪声”矩阵进行经验谱分析,引入平均谱半径(MSR)从宏观角度表征系统状态。为了实现异常的自动申报,设计了基于MSR的异常指示器,并计算了相应的置信度$1-α$。该方法能够在早期阶段检测到异常,并且对随机波动和测量误差具有鲁棒性。IEEE 300节点、118节点和57节点测试系统的综合数据算例验证了该方法的有效性和优越性。
英文摘要:
It is important for detecting the anomaly in power systems before it expands and causes serious faults such as power failures or system blackout. With the deployments of phasor measurement units (PMUs), massive amounts of synchrophasor measurements are collected, which makes it possible for the real-time situation awareness of the entire system. In this paper, based on random matrix theory (RMT), a data-driven approach is proposed for anomaly detection in power systems. First, spatio-temporal data set is formulated by arranging high-dimensional synchrophasor measurements in chronological order. Based on the Ring Law in RMT for the empirical spectral analysis of `signal+noise' matrix, the mean spectral radius (MSR) is introduced to indicate the system states from the macroscopic perspective. In order to realize anomaly declare automatically, an anomaly indicator based on the MSR is designed and the corresponding confidence level $1-α$ is calculated. The proposed approach is capable of detecting the anomaly in an early phase and robust against random fluctuations and measuring errors. Cases on the synthetic data generated from IEEE 300-bus, 118-bus and 57-bus test systems validate the effectiveness and advantages of the approach.