arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1907.05486physics.app-phphysics.class-phphysics.flu-dyn
收藏

加热亲水基底上静止水滴蒸发的计算与实验研究

A Combined Computational and Experimental Investigation on Evaporation of a Sessile Water Droplet on a Heated Hydrophilic Substrate

Manish Kumar, Rajneesh Bhardwaj

摘要:

我们的数值和实验研究蒸发的固着液滴加热基板上。我们开发了一个有限元(FE)模型,在二维轴对称坐标系中,以解决耦合传输的液滴和基板中的热量,并在周围环境中的液体蒸汽的质量,同时假设扩散限制,准稳态蒸发的液滴。双向耦合是使用一个迭代方案和下松弛来确保数值稳定性。针对已发表的蒸发质量通量和液-气界面温度的空间分布,对有限元模型进行了验证。我们讨论的情况下,双向耦合是显着准确的比单向耦合。在实验中,我们可视化的侧视图的蒸发微升水滴使用高速相机在不同的基板温度和记录的温度的液-气界面从顶部使用红外相机。我们研究的依赖性反转的温度分布在整个液体-气体界面上的基板厚度的润湿半径的比率,基板的热导率的液滴和接触角的比率。不同衬底温度下蒸发质量速率的测量值与计算值的比较表明,蒸发质量速率随衬底温度非线性增加,有限元模型预测的值与实验数据接近。通过对测量结果的时间平均蒸发质量速率的比较表明,在模型中应考虑界面处的蒸发冷却和扩散系数随温度的变化,以准确地捕获测量结果。

英文摘要:

We numerically and experimentally investigate evaporation of a sessile droplet on a heated substrate. We develop a finite element (FE) model in two-dimensional axisymmetric coordinates to solve coupled transport of heat in the droplet and substrate, and of the mass of liquid vapor in surrounding ambient while assuming diffusion-limited, quasi-steady evaporation of the droplet. The two-way coupling is implemented using an iterative scheme and under-relaxation is used to ensure numerical stability. The FE model is validated against the published spatial profile of the evaporation mass flux and temperature of the liquid-gas interface. We discuss cases in which the two-way coupling is significantly accurate than the one-way coupling. In experiments, we visualized side view of an evaporating microliter water droplet using a high-speed camera at different substrate temperatures and recorded temperature of the liquid-gas interface from the top using an infrared camera. We examine the dependency of inversion of the temperature profile across the liquid-gas interface on the ratio of the substrate thickness to the wetted radius, the ratio of the thermal conductivity of the substrate to that of the droplet and contact angle. A comparison of measured evaporation mass rate with the computed values at different substrate temperature show that the evaporation mass rate increases non-linearly with respect to the substrate temperature, and FE model predicts these values close to the experimental data. Comparisons of time-averaged evaporation mass rate obtained by the previous and present models against the measurements suggest that the evaporative cooling at the interface and variation of diffusion coefficient with temperature should be taken into account in the model in order to accurately capture the measurements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑