arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1907.00367astro-ph.SR
收藏

探讨韵律对喷发活动区NOAA AR 11158光球能量和螺旋度注入估算的影响

Probing the effect of cadence on the estimates of photospheric energy and helicity injections in eruptive active region NOAA AR 11158

E. Lumme, M. D. Kazachenko, G. H. Fisher, B. T. Welsch, J. Pomoell, E. K. J. Kilpua

摘要:

在这项工作中,我们研究了如何输入数据的节奏影响光球能量和螺旋度注入估计爆发NOAA活动区11158。我们从\emph{Solar Dynamics Observatory}(SDO)航天器上的\emph{Helioseismic and Magnetic Imager}(HMI)仪器上采集了新颖的2.25分钟矢量磁图和多普勒数据,以创建2.25分钟至24小时可变节奏的输入数据集。我们采用国家的最先进的数据处理,速度和电场反演方法,从这些数据集的能量和螺旋度注入的估计。我们发现,通过使用法拉第定律再现所观察到的磁场演化的电场反演方法对于可变节奏更稳定:PDFI(PTD-Doppler-FLCT-Ideal)电场反演方法对2.25分钟到2小时的节奏产生一致的注入估计,这意味着作用于2小时以下时间尺度的光球过程对注入贡献很小,或者它们低于输入数据和PDFI方法的灵敏度。另一方面,从DAVE 4VM(矢量磁图的差分仿射速度估计)的输出导出的电场估计值(不完全满足法拉第定律)在2.25分钟至2小时的节奏范围内产生能量和螺旋度注入估计值的显著变化。我们还提出了第三种新的基于DAVE 4VM的电场估计,它纠正了原始DAVE 4VM估计的不良感应性。该方法对节奏的变化不太敏感,但对于所考虑的最低节奏($\geq$ 2小时)仍然面临显著问题。我们发现几个潜在的问题,在PDFI和DAVE 4VM为基础的注射估计,并得出结论,两者的质量应进一步调查在受控环境。

英文摘要:

In this work we study how the input data cadence affects the photospheric energy and helicity injection estimates in eruptive NOAA active region 11158. We sample the novel 2.25-minute vector magnetogram and Dopplergram data from the \emph{Helioseismic and Magnetic Imager} (HMI) instrument onboard the \emph{Solar Dynamics Observatory} (SDO) spacecraft to create input datasets of variable cadences ranging from 2.25 minutes to 24 hours. We employ state-of-the-art data processing, velocity and electric field inversion methods for deriving estimates of the energy and helicity injections from these datasets. We find that the electric field inversion methods that reproduce the observed magnetic field evolution through the use of Faraday's law are more stable against variable cadence: the PDFI (PTD-Doppler-FLCT-Ideal) electric field inversion method produces consistent injection estimates for cadences from 2.25 minutes up to 2 hours, implying that the photospheric processes acting on time scales below 2 hours contribute little to the injections, or that they are below the sensitivity of the input data and the PDFI method. On other hand, the electric field estimate derived from the output of DAVE4VM (Differential Affine Velocity Estimator for Vector Magnetograms), which does not fulfil Faraday's law exactly, produces significant variations in the energy and helicity injection estimates in the 2.25-minute to 2-hour cadence range. We present also a third, novel DAVE4VM-based electric field estimate, which corrects the poor inductivity of the raw DAVE4VM estimate. This method is less sensitive to the changes of cadence, but still faces significant issues for the lowest of considered cadences ($\geq$2 hours). We find several potential problems in both PDFI- and DAVE4VM-based injection estimates and conclude that the quality of both should be surveyed further in controlled environments.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑