arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1905.07871astro-ph.HEastro-ph.GAphysics.atom-ph
收藏

Fe-L络合物的X射线谱

X-ray spectra of the Fe-L complex

Liyi Gu, A. J. J. Raassen, Junjie Mao, Jelle de Plaa, Chintan Shah, Ciro Pinto, Norbert Werner, Aurora Simionescu, Francois Mernier, Jelle S. Kaastra

摘要:

Hitomi对英仙座星系团的研究结果提高了我们对原子物理学的了解,这对于精确诊断用高分辨率X射线光谱仪观察到的热天体物理等离子体至关重要。然而,建模的不确定性仍然存在,无论是在Hitomi的光谱窗口内,但特别是超出。光谱建模中的一个主要挑战是Fe-L光谱,其基本上是不同电离状态的Fe离子的n>2到n=2跃迁的复杂集合,受到一系列原子过程的影响,例如碰撞激发、共振激发、辐射复合、双电子复合和内壳层电离。在本文中,我们进行了大规模的理论计算的每个过程与灵活的原子代码(FAC),专注于离子的Fe XVII到Fe XXIV,形成的主体的Fe-L络合物。新的数据被发现是一致的,在20%以内与最近的个人R矩阵计算的主要Fe-L线。利用15个椭圆星系和星系团的高质量RGS数据对新的FAC计算结果进行了进一步的检验,发现新模型的拟合结果比现有的dac v3.04程序有了系统的改善,与现有程序相比,平均Fe丰度降低了12%,而O/Fe比提高了16%.将FAC拟合结果与R矩阵计算结果进行比较,我们发现两种理论模型之间的Fe丰度存在高达10%的温度依赖性差异。需要对观察到的光谱和有针对性的实验室测量进行进一步的专门测试,以解决这些差异,并最终为下一次高分辨率X射线光谱任务准备原子数据。

英文摘要:

The Hitomi results on the Perseus cluster lead to improvements in our knowledge of atomic physics which are crucial for the precise diagnostic of hot astrophysical plasma observed with high-resolution X-ray spectrometers. However, modeling uncertainties remain, both within but especially beyond Hitomi's spectral window. A major challenge in spectral modeling is the Fe-L spectrum, which is basically a complex assembly of n>2 to n=2 transitions of Fe ions in different ionization states, affected by a range of atomic processes such as collisional excitation, resonant excitation, radiative recombination, dielectronic recombination, and innershell ionization. In this paper we perform a large-scale theoretical calculation on each of the processes with the flexible atomic code (FAC), focusing on ions of Fe XVII to Fe XXIV that form the main body of the Fe-L complex. The new data are found to be consistent within 20% with the recent individual R-matrix calculations for the main Fe-L lines. By further testing the new FAC calculations with the high-quality RGS data from 15 elliptical galaxies and galaxy clusters, we note that the new model gives systematically better fits than the current SPEX v3.04 code, and the mean Fe abundance decreases by 12%, while the O/Fe ratio increases by 16% compared with the results from the current code. Comparing the FAC fit results to those with the R-matrix calculations, we find a temperature-dependent discrepancy of up to ~10% on the Fe abundance between the two theoretical models. Further dedicated tests with both observed spectra and targeted laboratory measurements are needed to resolve the discrepancies, and ultimately, to get the atomic data ready for the next high-resolution X-ray spectroscopy mission.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑