arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1904.12656physics.ins-detphysics.optics
收藏

用参考干涉仪提高扫频干涉光谱测量的分辨限

Enhancing the Resolution Limits of Spectral Interferometric Measurements with Swept-Wavelength Interrogation by Means of a Reference Interferometer

Nikolai Ushakov, Alexandr Markvart, Leonid Liokumovich

摘要:

本文提出了一种用波长调谐光谱干涉法测量干涉传感器读数时,补偿干涉噪声影响的方法。以非本征法布里-珀罗干涉仪(EFPI)为例进行了理论分析和原理验证实验。提出了两种方案,包括信号和参考干涉仪,在不同的光通道的询问单元切换。该方法是基于这样一个事实,即一些的波动的参考和信号干涉仪的光程差(OPD)的测量值的波动产生相关的参数。可以从信号干涉仪的测量OPD中减去参考干涉仪测量OPD的波动。文中考虑了OPD各参数的涨落,论证了OPD测量值产生的噪声的相关性。第一个方案包含两个干涉仪具有相似的参数,并使三倍的分辨率提高在所进行的实验中,当干涉仪的OPD的差异在约10 nm内变化。第二种方案包含两个OPD不同的干涉仪,使得除了主导的OPD误差之外,所有的OPD波动都产生不相关的OPD误差。第二种方案的分辨率提高了一倍,实验证明,当干涉仪OPD的差异是在1 \mum以上的变化。所提出的方法可以用于提高具有相对大的OPD(大于200-300 \mum)的干涉传感器的分辨率,这对于远程材料和表面检测是有利的。

英文摘要:

An approach for compensating the influence of the interrogator noises on the readings of interferometric sensors, interrogated by means of spectral interferometry with wavelength tuning is proposed. Both theoretical analysis and a proof-of-principle experiment were performed for the example of extrinsic Fabry-Perot interferometers (EFPI). Two schemes, comprising of a signal and a reference interferometers, switched in different optical channels of the interrogating unit, were proposed. The approach is based on the fact that the fluctuations of some of the interrogator parameters produce correlated fluctuations of the reference and signal interferometers optical path differences (OPD) measured values. The fluctuations of the reference interferometers measured OPD can be subtracted from the measured OPD of the signal interferometer. The fluctuations of different parameters of the interrogator are considered, the correlation properties of the produced noises of the measured OPD values are demonstrated. The first scheme contains two interferometers with similar parameters and enabled a three-fold resolution improvement in the performed experiments, when the difference of the interferometers OPDs was varied within about 10 nm. The second scheme contains two interferometers with OPDs difference such that all interrogator fluctuations, except for the dominating one produce uncorrelated OPD errors. With the second scheme a two-fold resolution improvement was experimentally demonstrated, when the interferometers OPDs difference was varied within more than 1 \mum. The proposed approach can be used for improving the resolution of interferometric sensors with relatively large OPDs (greater than 200-300 \mum), which can be advantageous for remote materials and surface inspection.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑