Soft robotic systems offer benefits over traditional rigid systems through reduced contact trauma with soft tissues and by enabling access through tortuous paths in minimally invasive surgery. However, the inherent deformability of soft robots places both a greater onus on accurate modelling of their shape, and greater challenges in realising intraoperative shape sensing. Herein we present a proprioceptive (self-sensing) soft actuator, with an electrically conductive working fluid. Electrical impedance measurements from up to six electrodes enabled tomographic reconstructions using Electrical Impedance Tomography (EIT). A new Frequency Division Multiplexed (FDM) EIT system was developed capable of measurements of 66 dB SNR with 20 ms temporal resolution. The concept was examined in two two-degree-of-freedom designs: a hydraulic hinged actuator and a pneumatic finger actuator with hydraulic beams. Both cases demonstrated that impedance measurements could be used to infer shape changes, and EIT images reconstructed during actuation showed distinct patterns with respect to each degree of freedom (DOF). Whilst there was some mechanical hysteresis observed, the repeatability of the measurements and resultant images was high. The results show the potential of FDM-EIT as a low-cost, low profile shape sensor in soft robots.
Flexible electrical impedance tomography for tactile interfaces
The University of Edinburgh(爱丁堡大学);Institute for Imaging, Data and Communications(成像、数据与通信研究所);Institute for Integrated Micro and Nano Systems(集成微纳系统研究所)
Incorrectly sized balloon catheters can lead to increased post-surgical complications, yet even with preoperative imaging, correct selection remains a challenge. With limited feedback during surgery, it is difficult to verify correct deployment. We propose the use of integrated impedance measurements and Electrical Impedance Tomography (EIT) imaging to assess the deformation of the balloon and determine the size and shape of the surrounding lumen. Previous work using single impedance measurements, or pressure data and analytical models, whilst demonstrating high sizing accuracy, have assumed a…
Beihang University(北京航空航天大学);National Research Center for Rehabilitation Technical Aids(国家康复辅具研究中心)
Stiffness variation and real-time position feedback are critical for any robotic system but most importantly for active and wearable devices to interact with the user and environment. Currently, for compact sizes, there is a lack of solutions bringing high-fidelity feedback and maintaining design and functional integrity. In this work, we propose a novel minimal clutch with integrated stiffness variation and real-time position feedback whose performance surpasses conventional jamming solutions. We introduce integrated design, modeling, and verification of the clutch in detail. Preliminary expe…
By learning Variable Impedance Control policy, robot assistants can intelligently adapt their manipulation compliance to ensure both safe interaction and proper task completion when operating in human-robot interaction environments. In this paper, we propose a DMP-based framework that learns and generalizes variable impedance manipulation skills from human demonstrations. This framework improves robots$'$ adaptability to environment changes(i.e. the weight and shape changes of grasping object at the robot end-effector) and inherits the efficiency of demonstration-variance-based stiffness estim…
Fraunhofer Institute for Production Systems and Design Technology (IPK)(弗劳恩霍夫生产系统与设计技术研究所(IPK));Daegu Gyeongbuk Institute of Science and Technology(大邱庆北科学技术院)
An important performance metric for series-elastic actuators is the range of impedance which they can safely render. Advanced torque control, using techniques such as the disturbance observer, improve torque tracking bandwidth and accuracy, but their impact on safe impedance range is not established. However, to define a safe impedance range requires a practical coupled stability condition. Here, passivity-based conditions are proposed for two variants of DOB torque control, and validated experimentally in a high-stiffness environment. While high-gain PD torque control has been shown to reduce…
The University of Texas at Austin(得克萨斯大学奥斯汀分校);University of Michigan(密歇根大学)
The natural impedance, or dynamic relationship between force and motion, of a human operator can determine the stability of exoskeletons that use interaction-torque feedback to amplify human strength. While human impedance is typically modelled as a linear system, our experiments on a single-joint exoskeleton testbed involving 10 human subjects show evidence of nonlinear behavior: a low-frequency asymptotic phase for the dynamic stiffness of the human that is different than the expected zero, and an unexpectedly consistent damping ratio as the stiffness and inertia vary. To explain these obser…
Learning Variable Impedance Skills from Demonstrations with Passivity Guarantee
School of Artificial Intelligence, University of Chinese Academy of Sciences(中国科学院大学人工智能学院);Institute of Automation, Chinese Academy of Sciences(中国科学院自动化研究所)
The utility of Human-in-the-loop telerobotic systems (HiLTS) is driven in part by the quality of feedback it can provide to the operator. While the dynamic interaction between robot and environment can often be sensed or modeled, the dynamic coupling of the human-robot interface is often overlooked. Enabling dexterous manipulation through HiLTS however, will require careful consideration of human haptic perception as it relates to the human's changing limb impedance at the human-robot interface. In this manuscript, we present results from a stiffness perception task run on a simple 1-DoF rotat…
University of Birmingham(伯明翰大学);Technology Innovation Institute(技术创新研究院);Imperial College London(伦敦帝国理工学院)
Adapting upper-limb impedance (i.e., stiffness, damping, inertia) is essential for humans interacting with dynamic environments for executing grasping or manipulation tasks. On the other hand, control methods designed for state-of-the-art upper-limb prostheses infer motor intent from surface electromyography (sEMG) signals in terms of joint kinematics, but they fail to infer and use the underlying impedance properties of the limb. We present a framework that allows a human user to simultaneously control the kinematics, stiffness, and damping of a simulated robot through wrist's flexion-extensi…
Multi-Touch and Bending Sensing Using Electrical Impedance Tomography for Robotics
Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University in Prague(捷克技术大学布拉格分校电子学系);Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences(合肥物理科学研究院智能机器研究所)
Hong Kong University of Science and Technology(香港科技大学);Xeno Dynamics Co., Ltd(奇诺动力有限公司);Nankai University(南开大学)
Variable impedance control is advantageous for physical human-robot interaction to improve safety, adaptability and many other aspects. This paper presents a gain-scheduled variable stiffness control approach under strict frequency-domain constraints. Firstly, to reduce conservativeness, we characterize and constrain the impedance rendering, actuator saturation, disturbance/noise rejection and passivity requirements into their specific frequency bands. This relaxation makes sense because of the restricted frequency properties of the interactive robots. Secondly, a gain-scheduled method is take…