arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1903.10088physics.med-ph
收藏

TomoTherapy中MVCT的快速统计迭代重建

Fast Statistical Iterative Reconstruction for MVCT in TomoTherapy

Sho Ozaki, Akihiro Haga, Edward Chao, Calvin Maurer, Kanabu Nawa, Takeshi Ohta, Takahiro Nakamoto, Yuki Nozawa, Taiki Magome, Masahiro Nakano, Keiichi Nakagawa

摘要:

统计迭代重建有望提高兆伏级计算机断层成像(MVCT)的图像质量。然而,迭代重建的挑战之一是其巨大的计算成本。本文的目的是通过结合几种迭代技术和优化重建参数来开发一种快速迭代重建算法。从TomoTherapy系统采集兆伏投影数据,并使用我们的统计迭代重建进行重建。总变异被用作正则化项,正则化项的权重通过评价信噪比(SNR)、对比度噪声比(CNR)以及使用Gammex和Cheese phantomy的空间分辨率的视觉评估来确定。采用自适应收敛参数的梯度下降、有序子集期望最大化(OSEM)和CPU/GPU并行化来加速本重建算法。迭代重建的SNR和CNR比滤波反投影(FBP)好几倍。GPU并行化代码与OSEM算法相结合,重建图像的速度比CPU计算快几百倍。通过500次迭代,提供了良好的收敛性,我们的方法在几秒钟内产生了512 $\times$ 512像素的图像。对于患者数据,本算法的图像质量明显优于FBP。通过微调参数,可以在几秒钟内获得断层治疗中迭代重建的图像。GPU迭代重建速度快,可用于临床,并大大改善MVCT图像。

英文摘要:

Statistical iterative reconstruction is expected to improve the image quality of megavoltage computed tomography (MVCT). However, one of the challenges of iterative reconstruction is its large computational cost. The purpose of this work is to develop a fast iterative reconstruction algorithm by combining several iterative techniques and by optimizing reconstruction parameters. Megavolt projection data was acquired from a TomoTherapy system and reconstructed using our statistical iterative reconstruction. Total variation was used as the regularization term and the weight of the regularization term was determined by evaluating signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and visual assessment of spatial resolution using Gammex and Cheese phantoms. Gradient decent with an adaptive convergence parameter, ordered subset expectation maximization (OSEM), and CPU/GPU parallelization were applied in order to accelerate the present reconstruction algorithm. The SNR and CNR of the iterative reconstruction were several times better than that of filtered back projection (FBP). The GPU parallelization code combined with the OSEM algorithm reconstructed an image several hundred times faster than a CPU calculation. With 500 iterations, which provided good convergence, our method produced a 512$\times$512 pixel image within a few seconds. The image quality of the present algorithm was much better than that of FBP for patient data. An image from the iterative reconstruction in TomoTherapy can be obtained within few seconds by fine-tuning the parameters. The iterative reconstruction with GPU was fast enough for clinical use, and largely improve the MVCT images.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑