nEXO的Hamamatsu VUV4 MPPC的表征
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
摘要:
在本文中,我们报告的表征滨松VUV 4(S/N:S13370-6152)真空紫外线(VUV)敏感的硅光电倍增管(SiPMs)的一部分,为nEXO实验的液体氙闪烁光的检测解决方案的发展。各种SiPM特性,如:暗噪声、增益、相关雪崩、直接串扰和光子探测效率(PDE),在TRIUMF的专用装置中进行了测量。SiPM在$163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$范围内表征。在$3.1\pm0.2$ V和$\text{T}=163 \text{ }\text{K}$的过电压下,我们报告了在$0.161\pm0.005$触发脉冲后的$1 \upmu\text{s}$间期中每个脉冲的相关雪崩(CA)数量。在相同的设置下,暗噪声(DN)率为$0.137\pm0.002 \text{ Hz/mm}^{2}$。CA的数量和DN速率都在nEXO规范范围内。在平均波长为$189\pm7\text{ nm}$的$\text{T}=233 \text{ }\text{K}$上,测量了两种不同器械的Hamamatsu VUV 4 PDE。在过电压的$3.6\pm0.2$ V和$3.5\pm0.2$ V下,我们报告PDE为$13.4\pm2.6\text{ }\%$和$11\pm2\%$,分别对应于饱和PDE为$14.8\pm2.8\text{ }\%$和$12.2\pm2.3\%$。这两个值都远低于滨松所宣传的$24\text{ }\%$饱和PDE。更一般地,在$3.5\pm0.2$ V下测试的第二个器件的过电压低于nEXO PDE要求。第一种方法产生的PDE稍微接近于满足nEXO规范。这表明,经过适度的改进,Hamamatsu VUV 4 MPPC可以被认为是FBK-LF SiPM的替代品,用于nEXO探测器的最终设计。
英文摘要:
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。